Deadweight Tester

Prominent & Leading Wholesaler from Chennai, we offer fluke calibration p3031 and p3032 pneumatic deadweight testers and fluke calibration e-dwt electronic deadweight tester.

Fluke Calibration P3031 and P3032 Pneumatic Deadweight Testers

Request Callback

₹ 39000 / Piece Get Latest Price

Product Brochure
Model Name/NumberFluke Calibration P3031 and P3032 Pneumatic Deadweight Testers
Usage/ApplicationIndustrial
Packaging TypeBox
Brandfluke
I Deal InNew Only
Instrument weight24 lbs
Instrument size17.5 W x 12 D x 8.5 H
featuresMounted spirit level with adjustable feet
applicationsEnsures that the instrument is less susceptible to performance issues due to contamination

Minimum order quantity: 1 Piece

Fluke Calibration P3031 and P3032 Pneumatic Deadweight Testers Key features:
  • Pressure ranges to 2000 psi (140 bar)
  • 0.015% of reading accuracy (0.008% optional)
  • Screw press for fine pressure control
  • Piston flotation indicator
  • Mounted spirit level with adjustable feet
  • Series 3 non-magnetic stainless steel weights
Specifications:
Accuracy

Accuracy*

±0.015% of reading (±0.008% optional)

Mass and PCU Materials of Construction

Standard weight material

Series 3 non-magnetic austenitic stainless steel

Weight density

7.8 g/cm³

Optional fractional weights

Solution heat treated aluminum

Weight density

2.7 g/cm³

Models (P) P3031, P3032 (P & V)

Piston Material: Tungsten carbide
Cylinder Material: Martensitic steel
Coefficient of Expansion: 16.5 ppm/°C

 

General

Test port adaptors

1/8, 1/4, 3/8 and ½ NPT or BSP

Instrument weight

24 lbs

Instrument size

17.5 W x 12 D x 8.5 H

Mass set weight (typical)

65 lbs

 

Minimum Standard Weight Increments

P3016, P3031, P3032

1 psi, (0.1bar)

 

Optional Fractional Weights

P3014, P3015, P3025 Pressure

0.1 psi (0.01 bar)

 

Built-in Hand Pumps

Pressure mode

Max pressure 300 psi (20 bar)

Vacuum mode

To 90% vacuum

 

Operating Fluid for Liquid Lubricated Models

55-655

mineral oil (standard)

Krytox

for oxygen-safe applications (optional)

 

Options

PressCal Software

Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments.

Krytox

As operating fluid for liquid lubricated gas operated models.

Fluke Calibration E-DWT Electronic Deadweight Tester

Request Callback

₹ 30000 / Piece Get Latest Price

Product Brochure
Model Name/NumberFluke Calibration E-DWT Electronic Deadweight Tester
Usage/ApplicationIndustrial
Packaging TypeBox
Brandfluke
Operating temperature10 DegreeC to 40 DegreeC
Weight1 Q-RPT: 12 kg , 2 Q-RPT: 14 kg
DimensionsE-DWT footprint (W x D): 41.4 x 37.1 cm , E-DWT height: 26.9 cm , 33.6 cm
Communication portsRS232 (COM1, COM2)
Normal operating temperature range10 DegreeC to 40 DegreeC
Warm up time15 minute temperature stabilization recommended from cold power up.

Minimum order quantity: 1 Piece

Key features:

All the features you expect in today’s state-of-the-art instruments, including:

Accuracy and performance

  • One-year measurement uncertainty is ± 0.02% of reading from 10% to 100% with one Q-RPT, and from 1% to 100% with two Q-RPTs
  • Low torque variable volume allows for pressure generation up to 200 MPa (30,000 psi) with minimal physical effort
  • Separate fine adjustment tool for maximum, superfine control resolution
  • User defined resolution and ready limits enable user to optimize performance based on DUT specifications
Specifications:

General

Power requirements

To RPM4-E-DWT: 12 V DC 1.2 A

To AC to DC power supply: 100 V AC to 240 V AC, 50/60 Hz

Temperature range

Storage: - 20°C to 70°C

Operating: 10°C to 40°C

Relative humidity

Storage: 0% to 100%

Operating: 0% to 70%

Weight

1 Q-RPT: 12 kg (26 lb) approximate

2 Q-RPT: 14 kg (30 lb) approximate

Dimensions

E-DWT footprint (W x D): 41.4 x 37.1 cm (16.3 x 14.6 in)

E-DWT height: 26.9 cm (10.6 in), 33.6 cm (13.2 in) to max variable volume handle height

Pressure ranges dependent on Q-RPT(s) included in RPM4-E-DWT.

200 MPa (30,000 psi) maximum with standard variable volume

100 MPa (15,000 psi) maximum with high volume (-HV) variable volume

Operating medium

Delivered filled with oil (di-ethyl-hexyl sebacate) or dry

Standard E-DWT-H compatible with Sebacate, silicon oils, propylene glycol, fully fluorinated liquids, partially fluorinated liquids, isopropyl alcohol , and distilled water. Option for Skydrol or mineral oil preparation.

Reservoir capacity

300 cc (18 in3)

Variable volume displacement

Standard: 3 cc (0.18 in3), 200 MPa (30,000 psi) maximum

High: 7 cc (0.43 in3), 100 MPa (15,000 psi) maximum

Filling and priming pump displacement

3.7 cc (0.23 in3)

TEST pressure connection

DH500 female.

DH500 is a gland and collar type fitting for 6mm (1/4 in) coned and left hand threaded tubes equivalent to AE F250C, HIP HF4, 9/16-18 UNF, etc.


X

Contact Us

Lakshmi (Director)
Instruhub
New No 3, Appaiar Lane, Royapuram
Chennai - 600013, Tamil Nadu, India

Get Directions
Send Email
Share: