Density Meter

Prominent & Leading Wholesaler from Chennai, we offer anton paar benchtop density meter:dma 4101, anton paar compact digital density meter:dma 501, anton paar-mcr 72, anton paar-mcr 92, anton paar- dsr 502 and anton paar- htr.

Anton paar Benchtop density meter:DMA 4101

Request Callback

₹ 10000 / Piece Get Latest Price

Product Brochure
BrandAnton paar
VoltageAC 100 to 240 V, 50/60 Hz, fluctuation +-10 %, 190 VA
Usage/ApplicationLaboratory
Model Name/NumberDMA 4101
Dimensions526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in)
MaterialPTFE, borosilicate glass
Capacity22.04 kg (48.6 lbs)
TypeBenchtop density meter
Power SourceU-View(TM), FillingCheck(TM), ThermoBalance(TM), full-range viscosity correction
Power SupplyAC 100 to 240 V, 50/60 Hz, fluctuation +-10 %, 190 VA

Minimum order quantity: 1 Piece

Benchtop density meter:DMA 4101
  • 4-digit measurements in 20 seconds 
  • Ultra-fast measurement mode maximizes throughput
  • Best-in-class filling control provides reliable results
  • 200+ conversion tables for quicker results
Key features Fast and accurate benchtop density meters
  • Get market-leading precision, repeatability, and reproducibility with our patented Pulsed Excitation Method
  • Maximize throughput with an ultra-fast measurement mode
  • Define limits for different samples and make pass/fail QC decisions right away
  • 200+ pre-installed conversion tables show concentration values immediately
  • Achieve excellent results for highly viscous samples with the best viscosity correction on the market
  • Get reliable measurement results for high- and low-density samples as well as inhomogeneous, sedimenting, or particle-containing ones

Standards

2020 Chinese Pharmacopoeia

0601-relative density determination method4101, 4501, 5001

ABNT

NBR 140654101, 4501, 5001

NBR 156394101, 4501, 5001

AOAC

982.104101, 4501, 5001

ASBC

Beer-2B: Specific Gravity by digital density meter (1978)4101, 4501, 5001

Beer-5: Real Extract (B. Beer measured gravimetrically (1958), C. Real Extract determined refractometrically (1982))4101, 4501, 5001

ASTM

D12504101, 4501, 5001

D14754101, 4501, 5001

D25014101, 4501, 5001

D40524101, 4501, 5001

D48064501, 5001

D50024101, 4501, 5001

D59314101, 4501, 5001

D64484101, 4501, 5001

CPTC

SH/T 0604-2000 eqv. ISO 121854101, 4501, 5001

DIN

517574101, 4501, 5001

EBC

Chapter 1.64101, 4501, 5001

Chapter 8.2.24101, 4501, 5001

Chapter 9.43.24101, 4501, 5001

Spirits drinks: COMMISSION REGULATION (EC) No 2870/20004101, 4501, 5001


Technical specification

 Density           0 g/cm³ to 3 g/cm³

Temperature  0 °C to 100 °C (32 °F to 212 °F)

Power features           U-View™, FillingCheck™, ThermoBalance™, full-range viscosity correction

Special functions       QM compliance, temperature scan, built-in ambient pressure sensor, condition monitoring adjustment at high viscosity (only DMA 5001 )

Automation    Automatic sample changers

Modularity      pH, alcohol, CO2, O2, color, turbidity, refractive index

Typical measuring time/sample       20 s    

Minimum sample volume      Approx. 1 mL

Wetted materials        PTFE, borosilicate glass

Dimensions (L x W x H)         526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in)

Weight 22.04 kg (48.6 lbs)

Power supply AC 100 to 240 V, 50/60 Hz, fluctuation ±10 %, 190 VA

Display           10.1" TFT WXGA (1280 x 800 px); PCAP touchscreen

Controls         Touchscreen, optional keyboard, mouse, and barcode reader

Communication interfaces   5 x USB, Ethernet, CAN, RS232

Internal storage         More than 10,000 measuring values with camera images

 

Anton paar Compact digital density meter:DMA 501

Request Callback

₹ 30000 / Piece Get Latest Price

Product Brochure
BrandAnton paar
Usage/ApplicationLaboratory
Model Name/NumberCompact digital density meter DMA 501
Dimensions375 mm x 265 mm x 180 mm (14.8 in x 10.4 in x 7.0 in)
MaterialBorosilicate glass, PTFE
CapacityApprox. 1 mL
Model NumberDMA 501
Power SupplyAC 100 to 240 V; 47 to 63 Hz; DC 24V, 3A
UseIntegrated temperature and humidity sensor for intelligent condition monitoring Built-in pressure
Colorwhite

Minimum order quantity: 1 Piece

DMA 501
  • 3-digit digital density measurement from the market leader
  • Small is big: only 1 mL sample volume avoids wasting product
  • Big is bigger: 7” glove-friendly touchscreen for great usability
  • No manual calculations due to 60+ conversion tables
  • Ready for pasty, inhomogeneous, particle-containing samples

Benefits:

·        Upgrade your density measurements and leave your time-intensive, breakage-prone hydrometers behind. Over 60 integrated conversion tables, 400 freely configurable methods, and memory for up to 5000 data logs set the benchmark in this segment. Set up the device once with all your frequently used tests and return to them again and again to immediately see a clear “pass/fail” result based on your defined acceptable upper and lower limits. As DMA 501/1001 requires only 1 mL sample volume you won’t waste valuable product. Both instruments thrive in harsh environments and automatically compensate for external influences such as humidity, altitude, and ambient temperature. When linked to AP Connect, our lab execution software, all data is stored in a single digital space and accessible from any network computer. 

·        DMA 501 is your entry-ticket to 3-digit digital density measurement. Choose DMA 1001 for 4-digit accuracy and full compliance with international standards, including all relevant Pharmacopeia (US, EU, JP, CN), data integrity (21 CFR Part 11, GMP 4 annex 11&15, ALCOA+), and ASTM D4052 & D5002.

Standard:

ABNT

NBR 140651001

NBR 156391001

ASTM

D12501001

D14751001

D25011001

D40521001

D48061001

D50021001

D59311001

D64481001

Chinese Pharmacopoeia (ChP)

ChP 2020 (Vol IV) 0601501, 1001

DIN

517571001

IP

3651001

ISO

Technical specification:

DMA 501

Patents

EP3012612B1, AT520632B1, US10145771B2

Measuring range

Density: 0 g/cm³ to 3 g/cm³
Pressure: 0 bar to 10 bar (0 psi to 145 psi)

Temperature: 15 °C to 40 °C (59 °F to 104 °F)

Repeatability, s.d.*

Density: 0.0002 g/cm³
Temperature: 0.1 °C (0.2 °F)

Reproducibility, s.d.*

Density: 0.0004 g/cm³

Accuracy**

Density: 0.001 g/cm³
Temperature: 0.3 °C (0.6 °F)

Digital Resolution

Density: 0.0001 g/cm³
Temperature: 0.01 °C (0.01 °F)

U-View™

Yes

FillingCheck™

Yes

Full-range viscosity correction

Yes

Minimum sample volume

Approx. 1 mL

Integrated tables and functions

Density, Specific Gravity (SG), alcohol tables, sugar/extract tables, various acid/base tables, API functions

Wetted parts

Borosilicate glass, PTFE

Dimensions (L x W x H)

375 mm x 265 mm x 180 mm (14.8 in x 10.4 in x 7.0 in)

Weight

13.5 kg (29.8 lb)


Anton Paar-MCR 72

Request Callback

₹ 80000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
Model Name/NumberMCR 72
BrandAnton Paar
TypeModular Compact Rheometer
Size/Dimension380 x 660 x 530 mm
Weight33 kg

Minimum order quantity: 1 Piece

·        The robust one
·        Equipped with a ball bearing motor
·        For measurements in rotation (and oscillation for special applications)
·        Ideal to measure your samples’ flow behavior

Technical specifications

Specifications Units MCR 72

Bearing

-

Ball

EC motor (brushless DC) with high resolution optical encoder

-

✓

Rotation Mode

-

✓

Oscillation Mode

-

✓ (1

Direct Strain Controller

-

✓

Direct Stress Controller

-

✓

Maximum torque

mNm

125

Minimum torque, rotation

µNm

200

Minimum torque, oscillation

µNm

200

Torque resolution

nNm

100

Angular deflection, set value

µrad

1 to ∞

Angular deflection, resolution

nrad

614

Step rate, time constant

ms

100

Step strain, time constant

ms

100

Minimum angular velocity 

rad/s

10-4

Maximum angular velocity

rad/s

157

Minimum angular frequency (3

rad/s

10-3

Maximum angular frequency

rad/s

628

 


Anton Paar-MCR 92

Request Callback

₹ 80000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
Model Name/NumberMCR 92
BrandAnton Paar
TypeModular Compact Rheometer
Size/Dimension380 x 660 x 530 mm
Weight33 kg

Minimum order quantity: 1 Piece

·        The sensitive one
·        Equipped with a highly accurate air bearing motor for sensitive samples
·        For measurements in both rotation and oscillation
·        Ideal to investigate your samples’ structure

Technical specifications

Specifications Units MCR 92

Bearing

-

Air

EC motor (brushless DC) with high resolution optical encoder

-

✓

Rotation Mode

-

✓

Oscillation Mode

-

✓

Direct Strain Controller

-

✓

Direct Stress Controller

-

✓

Maximum torque

mNm

125

Minimum torque, rotation

µNm

1

Minimum torque, oscillation

µNm

1

Torque resolution

nNm

100

Angular deflection, set value

µrad

1 to ∞

Angular deflection, resolution

nrad

614

Step rate, time constant

ms

100

Step strain, time constant

ms

100

Minimum angular velocity (2

rad/s

10-4

Maximum angular velocity

rad/s

157

Minimum angular frequency (3

rad/s

10-4

Maximum angular frequency

rad/s

628

 


Anton Paar- DSR 502

Request Callback

₹ 78900 / Piece Get Latest Price

Product Brochure
Model Name/NumberDSR 502
BrandAnton Paar
TypeDynamic Shear Rheometer Measuring Head
Maximum Torque230 nNm
Min. torque rotation2 nNm
Torque resolution0.1 nNm

Minimum order quantity: 1 Piece

·        Modular rheometer measuring head with separate control unit
·        Full flexibility for integration into tailor-made setups
·        High sensitivity: Air-bearing-supported synchronous EC-motor
·        Accuracy in a vast viscosity range and oscillatory mode 
·        Quick integration and exchange of measuring geometries

·        Technical specifications

Technical Data

 

Unit

Rheometer Head (DSR)

Bearing

 

Air

EC motor

 

Yes

Maximum Torque

mNm

230

Min. torque rotation

nNm

10

Min. Torque oscillation

nNm

2

Torque resolution

nNm

0.1

Angular deflection
(set value)

µrad

0.1 to ∞

Angular resolution

nrad

10

Min. angular velocity

rad/s

10-9

Max. angular velocity

rad/s

314

Max. speed

1/min

3000

Min. angular frequency

rad/s

10-7

Max. angular frequency

rad/s

628

Toolmaster™

-

Yes

QuickConnect

 

Yes

Direct strain controller

-

Yes

 


Anton Paar- HTR

Request Callback

₹ 90900 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
Model Name/NumberHTR
BrandAnton Paar
Typeautomated high-throughput rheometer
Size/Dimension1800 mm x 1200 mm x 2000 mm
Weight900 kg

Minimum order quantity: 1 Piece

Anton Paar- HTR

The HTR automation series offers an optimized analysis workflow for rheological investigations based on Anton Paar’s MCR 702 rheometer. The extensive set of features and the built-in flexibility make it the ideal choice for sophisticated and high-throughput R&D or QC work.

Technical specifications

Dimensions (W x D x H)

1800 mm x 1200  mm x 2000 mm

Weight (net)

900 kg

Mains supply

400 V, 16 A, 50/60 Hz

Media interfaces

Compressed air, cleaning solvents

Waste disposal

Drain for liquids

Communication interface

Ethernet

Rheometer specifications

 

MCR 702 MultiDrive

Max. torque

230 mNm

Min. torque (rotation)

1 nNm

Min. torque (oscillation)

0.05 nNm

Max. angular velocity

314 rad/s

Max. angular frequency

628 rad/s

Normal force range

0.005 N to 50 N

Anton Paar-PSA 1190

Request Callback

₹ 66000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial Use
Packaging Typecarton box
brandanton paar
model namePSA 1190
weight55 kg
dimension890 mm x 530 mm x 430 mm
Number of lasers3

Minimum order quantity: 1 Piece

Anton Paar-PSA 1190

·        Multi laser system

·        Measurement range liquid: 0.04 µm to 2500 µm

·        Measurement range dry: 0.1 µm to 2500 µm

Technical specifications:

 

PSA 1190

Measurement principle

Laser diffraction

Measuring range (dry)

0.1 μm to 2500 μm

Measuring range (wet)

0.04 μm to 2500 μm

Dry dispersion

Venturi/Freefall

Liquid dispersion

2 peristaltic pumps/ultrasonic transducer/stirrer

Repeatability

<1 %

Accuracy

<3 %

Measuring time

<1 min

Number of lasers

3

Laser safety classification

FDA Title 21 CFR - Part 1040 & EN 60825-1:2014

Laser class, closed cover 

Class 1 of EN 60825-1:2014

Laser class, open cover 

Class 3R of EN 60825-1:2014

Digital data security

FDA Title 21 CFR - Part 11

Electromagnetic compatibility 

EN 61326-1:2013

Low voltage

EN 61010-1:2010 & EN 61010-2-081:2015

Dimensions (L x D x H) 

890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in

Weight

~55 kg

Anton Paar-SurPASS 3 Standard

Request Callback

₹ 110000 / Piece Get Latest Price

Product Brochure
Model Name/NumberSurPASS 3 Standard
Weight26 kg
Packaging Typecarton box
brandanton paar
product typeElectrokinetic Analyzer for Solid Surface Analysis
dimensions600 mm x 432 mm x 245 mm (D x W x H)
Mains supplyAC 115 to 230 V, 50 to 60 Hz, 200 VA

Anton Paar-SurPASS 3 Standard


Technical specifications

 

SurPASS 3

Measuring range

Streaming potential

±2000 mV ± (0.2 % + 4 μV)

Streaming current

±2 mA ± (0.2 % + 1 pA)

Cell resistance

5 Ω to 20 MΩ ± (2 % + 0.5 Ω)

Pressure measurement

3500 mbar ± (0.2 % + 0.5 mbar)
External pressure supply (compressed Nâ‚‚) is required for differential pressure > 1200 mbar

pH value

pH 2 to pH 12

Conductivity

0.1 mS/m to 1000 mS/m

Temperature

20 °C to 40 °C
Temperature control option is available

Sample size requirements

Porous films, foils, or plates

Rectangular-shaped: 20 mm x 10 mm (max. thickness: 2 mm )
Disk-shaped: 14 mm or 15 mm in diameter (max. thickness: 2 mm)

Non-porous films, foils, or plates

Rectangular-shaped: 20 mm x 10 mm (max. thickness: 2 mm) or
min. 35 mm x 15 mm (max. thickness: 40 mm)

Disk-shaped: 14 mm or 15 mm in diameter (max. thickness: 2 mm) or
min. 17 mm in diameter (max. thickness: 40 mm)

Particles

Particle size: min. 25 μm

Fibers

Min. 100 mg

Fabrics

Min. 30 mm x 30 mm

Hollow fiber membranes

Length: min. 170 mm

Ceramic membranes

Flat sheet: 14 mm in diameter
Single channel: outer diameter 10 mm or 13 mm
Multichannel: outer diameter 25 mm or 30 mm

Cylindrical cores

Height: max. 4 inch
Diameter: 1 inch

Flexible tubing

Length: min. 100 mm
Outer diameter: 0.7 mm to 6 mm

Pre-filled syringes

Syringe barrel “1.0 mL long” (ISO 11040-4)

Vials

2R/4R vials (ISO format), outer diameter 16 mm


Anton Paar- FRS 1600

Request Callback

₹ 80900 / Piece Get Latest Price

Usage/ApplicationIndustrial
Model Name/NumberFRS 1600
BrandAnton Paar
TypeHigh Temperature Viscometer and Rheometer
Size/Dimension680 x 1950 x 920 mm
Weight120 kg

Minimum order quantity: 1 Piece

Technical specifications

 

Unit

FRS 1600

Bearing

-

Air

EC motor (brushless DC) with high resolution optical encoder

-

✔

Permanent torque (60 min), no signal drift

-

✔

EC mode (controlled shear rate and shear stress)

-

✔

Rotation mode

-

✔

Oscillation mode

-

✔

Measuring of newtonian samples

-

✔

Measuring of non-newtonian samples

-

✔

Maximum torque

mNm

230

Minimum torque, rotation

nNm

10

Minimum torque, oscillation

nNm

2

Torque resolution

nNm

0.1

Viscosity range

Pa.s

0.001–107

Angular deflection, set value

µrad

0.1 to ∞

Angular deflection, resolution

nrad

10

Minimum angular velocity

rad/s

10-9

Maximum angular velocity

rad/s

314

Minimum speed (CSS/CSR)

1/min

10-9

Maximum speed FRS

1/min

300

Maximum speed measuring head

1/min

3000



Anton Paar- Mechanical Surface Testing Platforms Step 301

Request Callback

₹ 100000 / Piece Get Latest Price

Brandanton paar
Packaging Typecarton box
model nameMechanical Surface Testing Platforms Step 301
colorwhite
featuresVarious microscope configuration choices

Anton Paar- Mechanical Surface Testing Platforms Step 301

·        One measuring head can be mounted
·        Motorized X (75 mm), Y (75 mm) and Z (30 mm) stages
·        Various microscope configuration choices  
·        Anti-vibration table


Step platforms are the basis for Anton Paar’s mechanical surface measuring heads and are the most versatile on the market. With these platforms you can conduct up to four testing methods on a single platform: scratch, indentation, Vickers hardness, and basic tribology. Take advantage of the improved sample navigation features while retaining the high positioning accuracy (<1 µm) over a great length. Customized synthetic granite ensures enhanced vibration damping. 


Key features
  • The most versatile surface testing platform on the market

Revolutionize your testing capabilities with an all-in-one platform! Combine scratch, instrumented indentation, automatic conventional hardness, and tribology testing over a wide force range. Save time by transitioning from one method to another with zero setup adjustments. Whether you buy a single head or a full all-in-one setup, our Step platform solution keeps the door open for a future upgrade.

  • Navigate two times faster

Go twice as fast when it comes to sample visualization thanks to the unique features of the dual view microscope: continuous zoom with a remarkable magnification range (20x to 10000x) and seamless transition from a panoramic surface overview to maximum magnification.

  • Help when you need it

Whether it's technical, after-sales, or application support you need, we have 37 subsidiaries around the globe ready to help wherever you are. We’re confident in the high quality of our instruments. That’s why we provide a full 3-year warranty.

  • Reduce costs via automation

We can help you integrate your Step platform into the QC area of your production plant for automatic sample handling, loading, and testing. This reduces costs and increases measurement throughput.

  • Reduce effort, save time

You can mount differently sized samples on the instrument and measure them directly off the production line. Unlock bespoke solutions designed specifically for your sample holding needs, available upon request.

Anton Paar- Litesizer DLS 500

Request Callback

₹ 80000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial Use
Packaging Typecarton box
model nameLitesizer DLS 500
brandAnton Paar
Weight18 kg
Dimensions460 mm, 485 mm, 135 mm
Light sourceSemiconductor laser diode / 40 mW, 658 nm

Minimum order quantity: 1 Piece

Technical specifications


 

Litesizer DLS 500

Particle size specifications

Measurement principle

Dynamic Light Scattering (DLS)

Measuring range

0.3 nm to 10 μm (particle diameter)

Measurement angles

15°, 90°, 175°

 

Min. concentration

0.1 mg/mL (lysozyme) lower than 0.00001 % (0.1 ppm, Latex 100 nm)    

Max. concentration

50 % w/v (sample-dependent)

Min. sample volume

12 µL

Accuracy

Better than +/-2 % on NIST traceable standards

Repeatability

Better than +/-2 % on NIST traceable standards

 

Zeta potential specifications

Measuring principle

Electrophoretic Light Scattering (ELS) / cmPALS

Measuring range

>= +/-1000 mV

Mobility range

10 -11 m²/V.s to 2 x 10 -7 m²/V.s

Size range

3.8 nm to 100 µm (diameter)

Min. sample concentration

0.1 mg/mL (lysozyme)

Max. sample concentration

70 %w/v (sample-dependent)

Max. sample conductivity

200 mS/cm

Min. sample volume

50 µL (sample-viscosity-dependent)

Accuracy

Better than +/-10 %

Repeatability

+/-3 %

 


Anton Paar- PFD Plus

Request Callback

₹ 100000 / Piece Get Latest Price

Product Brochure
Weight10.1 kg
Brandanton paar
Dimension190 x 270 x 670 mm
FeaturesNo loss of CO2 or O2, due to pressurized filling
Model Name/NumberPFD Plus
typeFilling Device
usageDirect sample transfer from glass bottles, PET bottles, and cans

Anton Paar- PFD Plus

·        Direct sample transfer from glass bottles, PET bottles, and cans

·        No loss of COâ‚‚ or Oâ‚‚, due to pressurized filling

·        Additional splinter shield for maximum user protection

·        Long sample tube enabling transfer of maximum possible sample amount

The PFD Filling Device transfers your sample directly from a closed container – either a bottle or a can – into the measuring chamber of a measuring instrument. As the closure is sealed before piercing, no CO2 is lost during sample transfer, which makes PFD and PFD Plus the ideal filling devices for CO2/O2 meters and Packaged Beverage Analyzers.

Key features Direct sample filling from bottles and cans
  • Suitable for glass bottles, cans, and PET bottles of any size
  • Different bottle adapters for different bottle sizes available
  • No centering plate necessary

Safe operation of pressurized systems
  • High operator safety standard due to protective shield
  • Safety pin allows operation only with shield in place
  • Additional splinter shield for maximum user protection even if system is not placed in front of a wall (PFD Plus only)


Convenient use in lab and packaging areas

  • Only 6 ± 0.5 bar (87 ± 7 psi) relative pressure of pressurized air or nitrogen needed
  • Base plate surface layer consists of stainless steel
  • For filling soft drinks, beer, water, and carbonated bottled water directly from the package


Technical specifications

Maximum allowed volume of packages

Can

0.5 L

Glass bottle

1 L

PET bottle

3 L

Compressed air

6 ± 0.5 bar (87 ± 7 psi) relative pressure

Dimensions
(L x W x H)

190 x 270 x 670 mm
(7.5 x 10.6 x 26.4 inches)

Maximum height with piercing head in highest position

1020 mm
(40.2 inches)

Weight

10.1 kg (22.3 lbs)

Anton Paar-Micro Combi Tester MCT3

Request Callback

₹ 100000 / Piece Get Latest Price

Product Brochure
Brandanton paar
Packaging Typecarton box
model nameMicro Combi Tester MCT3
colorwhite
applicationFor characterization of hard coatings, thermal/plasma spray coatings, cementitious material, metals

Anton Paar-Micro Combi Tester MCT³


·        4-in-1 setup for instrumented indentation, conventional hardness, scratch & basic tribology testing
·        Measurement of hardness, elastic modulus, coating adhesion, scratch resistance, wear, and other surface mechanical properties  
·        For characterization of hard coatings, thermal/plasma spray coatings, cementitious materials, metals, and polymers



The Micro Combi Tester (MCT³) is a universal measurement head for full mechanical characterization of coatings and bulk samples. The unique wide load range of this instrument allows the determination of adhesion, scratch resistance, hardness, elastic modulus, friction, and wear for a wide range of samples. It is applicable to organic and inorganic, as well as soft and hard, coatings (between 1 µm and 20 µm), and bulk materials.


Technical specifications

Maximum load [N]

30

Load resolution [μN]

6

Load noise floor [rms] [μN]

100

Loading rate [N/min]

up to 300

Depth range [μm]

1000

Depth resolution [nm]

0.03

Depth noise floor [rms] [nm]

1.5

Data acquisition rate [kHz] 

192

Scratch speed [mm/min]

0.1 to 600

Options

Peltier heating up to 120 °C

✓

Heating stage up to 200 °C

✓

Cooling down to -120 °C

✓

Liquid testing

✓

Anton Paar-Bioindenter UNHT3 Bio

Request Callback

₹ 100000 / Piece Get Latest Price

Product Brochure
Brandanton paar
Packaging Typecarton box
model nameBioindenter UNHT3 Bio
featureMeasurement of soft and biological materials

Key features

Anton Paar Bioindenter: Dedicated to your research

Investigations with the Anton Paar Bioindenter result in valuable conclusions on the mechanical behavior of very soft biological materials. This can be especially important when it comes to gaining a better understanding of the human body, e.g. for improving diagnosis, developing new drugs, engineering tissues and much more.

The indentation procedure: Optimized for your measurements

The Anton Paar Bioindenter offers a wide choice of indentation procedures including quasi-static, dynamic and user defined indentation modes. On the top of the standard analysis models, it includes Hertz model and automatic pull-off adhesion analysis. The convenient contact point determination makes the Bioindenter an instrument you will enjoy working with.

The measurement system: A class of its own

The measurement unit of the instrument itself is designed for high-precision nanoindentation in biology and medicine. The integrated true force sensor is able to apply a maximum load of up to 20 mN. The displacement sensor allows a large travel range. Furthermore, the Anton Paar Bioindenter provides good thermal stability to study creep and flow properties. 

Software: The key to your results

With the powerful but easy to handle software, you have full control of the indentation procedures (load, displacement, etc.). The results are automatically analyzed and a statistical module for fast overview of your the data and results is also provided. User-defined ASCII exports can be made and multiple users can work with the instruments with controlled access rights. The elastic modulus can also be calculated from the loading part of the indentation curve using the Hertz’s model, which is more appropriate for biological materials than the commonly used Oliver & Pharr approach.

Different kinds of indenters: The choice is yours

The Anton Paar Bioindenter works with different kinds of indenters depending on your materials and needs. There are spherical indenters with radii from 0.01 mm up to 0.5 mm and larger, flat-punch (flat-ended cylinder) indenters, Berkovich indenters, Vickers indenters, cube-corner indenters, and also custom-made indenters to suit even the most demanding applications (large radii spheres, cylinders, etc.).

The versatile Step platform concept

Select the suitable solution from our platform portfolio based on the test parameters and expected sensitivity. Step platforms offer solutions for single applications used in dedicated laboratories as well as shared instruments across multiple departments. Their modularity enables high-sensitivity indentation testing on bi omaterials, along with characterization of hard polymer samples and scratch testing – all on a single platform.


Technical specifications

Force

Max. force

20 mN

Resolution

down to 0.001 µN

Noise floor

0.1 [rms] [μN]*

Depth

Max. depth

100 μm

Resolution

down to 0.006 nm

Noise floor

0.25 [rms] [nm]*

*Noise floor value specified under ideal laboratory conditions and using an anti-vibration table.

Anton Paar- Nano Scratch Tester NST3

Request Callback

₹ 100000 / Piece Get Latest Price

Product Brochure
Brandanton paar
Packaging Typecarton box
model nameNano Scratch Tester NST3
Maximum load [mN]1000

Anton Paar- Nano Scratch Tester NST3

·        Measurement of coating adhesion and scratch resistance
·        Full panorama image synchronized with all other signals such as penetration depth and friction force
·        Ideal for thin coatings below 1000 nm thickness  
·        Force measurement up to 1000 mN


The Nano Scratch Tester (NST3) is particularly suited for characterizing the scratch resistance and adhesion of thin films and coatings with a typical thickness below 1000 nm. Analyze organic and inorganic, as well as soft and hard coatings. The unique design of the nano-scratch measurement head includes two sensors for force and depth measurements associated with a state-of-the-art piezoelectric actuator – get results in milliseconds, plus great accuracy and great flexibility.Combine the NST3 head with another scratch or indentation testing head to fully cover the nano, micro, and macro range. The versatility of the Step platform even allows you to add an AFM to investigate surface topography.


Technical specifications

Maximum load [mN]

1000

Load resolution [μN]

0.01

Load noise floor [rms] [μN]

0.1

Loading rate [N/min]

Up to 100

Maximum friction force [mN]

1000

Friction force resolution [μN]

1

Maximum depth [μm]

600

Depth resolution [nm]

0.1

Depth noise floor [rms] [nm]

1.5

Data acquisition rate [kHz]

192

Scratch speed [mm/min]

0.1 to 600

Anton Paar- Brabender MetaStation 16

Request Callback

₹ 100000 / Piece Get Latest Price

Product Brochure
Model Name/NumberBrabender MetaStation 16
BrandAnton Paar
TypeModular Torque Rheometer
FeaturesExtrusion insights: Your shortcut to improved product quality
Size/Dimension600 mm x 1500 mm x 1370 mm
Weight311 kg

·        Drive for lab-scale mixers, single- and twin-screw extruders

·        Ready for higher torque requirements compared to MetaStation 8

·        Speed control: 0.2 min-1 to 400 min-1 with 500 Nm max. torque

·        Smart drive and control unit to gain deep process knowledge

·        MetaBridge for analyzing time-dependent process variables

The market-leading Brabender MetaStation is a versatile, modular drive unit and torque rheometer for determining the processability and material characteristics of different plastics and plastifiable substances, compliant with key ASTM standard methods. Tailor it to your specific PVC, rubber, or thermoset testing needs, using our portfolio for varied blade geometries, mixer sizes, and temperature control. 


Key features

·        Your path to worldwide product qualification ·        From PVC to thermosets: MetaStation's versatile mixer attachments ·        Extrusion insights: Your shortcut to improved product quality ·        MetaBridge: Your gateway to data excellence ·        Specialized solutions for demanding applications

 


Technical specifications

 

MetaStation 4

MetaStation 8

MetaStation 16

Drive output

4.2 kW

8 kW

16 kW

Torque and speed

200 Nm, 0.2 min-1 to 185 min-1

400 Nm, 0.2 min-1  to 200 min-1

400 Nm, 0.2 min-1  to 400 min-1
500 Nm, 0.2 min-1  to 275 min-1

Speed deviation

0.2 % through digital feedback

Integrated temperature control

6 zones

8 zones

Connectivity

- MetaBridge Connect
- WebAPI
- Labfolder (LIMS)

Safety devices

- Emergency motor stop button
- Non-contact magnetic safety switch on the cover of the measuring system



Anton Paar-CboxQC At-line

Request Callback

₹ 56700 / Piece Get Latest Price

Usage/ApplicationIndustrial
Brandanton paar
Model Name/NumberCboxQC At-line
Dimension262 mm x 209 mm x 176 mm
Weight2.7 kg (6 lbs)
Protection classIP67

Minimum order quantity: 1 Piece

·        For measuring dissolved CO2 and O2 in the production environment
·        Sampling directly from process lines, tanks, kegs, and casks  
·        Protection class IP67 and rubber housing


Technical specifications

At-line

 

Measuring range

CO2

0 g/L to 12 g/L (0 vol. to 6 vol.) at 30 °C (86 °F)

0 g/L to 20 g/L (0 vol. to 10 vol.) <15 °C (59 °F)

O2

0 ppm to 4 ppm

Temperature

–3 °C to 40 °C (27 °F to 104 °F), acc. ±0.2 °C

Pressure

0 bar to 10 bar absolute (0 psi to 145 psi), acc. 0.01 bar

Repeatability s.d.

CO2

±0.04 g/L (0.02 vol.)

 

O2

2 ppb (in the range <200 ppb)    

Resolution

CO2            

0.01 g/L

 

O2

0.1 ppb (in the range from 0 ppb to 99.9 ppb)

Sample volume

>150 mL

Measuring units

CO2

g/L, vol., mg/L, kg/cm2, MPa, % w/w

O2

ppm, ppb, hPa, mg/L, μg/L, % Air-sat., % O2-sat.

Measuring time

90 seconds

Data memory

500 measurement data sets

Built-in support

FillingCheck™, CO2 | O2 Data Logger, threshold value functionality, system check

Portable use

Up to 11 hours continuous use


Anton Paar-CarboQC At-line

Request Callback

₹ 56000 / Piece Get Latest Price

Weight2.1 kg (4.6 lbs)
Brandanton paar
Model Name/NumberCarboQC At-line
Dimensions (L x W x H)262 mm x 209 mm x 176 mm (10.3 in x 8.2 in x 6.9 in)
Protection classIP67
Portable useUp to 11 hours continuous use

Minimum order quantity: 1 Piece

Anton Paar-CarboQC At-line

  • For measuring dissolved carbon dioxide in the production environment
  • Guided CO2 system check to ensure correct results
  • Protection class IP67 and rubber housing


Technical specifications:

 

At-line

Measuring range

CO2

0 g/L to 12 g/L (0 vol. to 6 vol.) at 30 °C (86 °F)
0 g/L to 20 g/L (0 vol. to 10 vol.) <15 °C (59 °F)

Temperature

–3 °C to 40 °C (27 °F to 104 °F), acc. ±0.2 °C

Pressure

0 bar to 10 bar absolute (0 psi to 145 psi), acc. 0.01 bar

Repeatability s.d.

CO2

±0.04 g/L (0.02 vol.)

Resolution

0.01 g/L

Sample volume

>150 mL

Measuring units

g/L, vol., mg/L, kg/cm2, MPa, % w/w

Measuring time

55 seconds

Data memory

500 measurement data sets

Built-in support

FillingCheck™, CO2 Data Logger, threshold value functionality, system check

Portable use

Up to 11 hours continuous use

Communication interfaces

1x RS-232 (CAN-open[1]), 1x USB; optional: 1x RFID, 1x Bluetooth

Protection class

IP67

Dimensions (L x W x H)

262 mm x 209 mm x 176 mm (10.3 in x 8.2 in x 6.9 in)

Weight

2.1 kg (4.6 lbs)

Anton Paar-OxyQC Wide Range

Request Callback

₹ 19999 / Piece Get Latest Price

Weight1.7 kg
BrandAnton Paar
Dimension262 mm x 209 mm x 176 mm
Model Name/NumberOxyQC Wide Range
Protection classIP67

Anton Paar-OxyQC Wide Range

·        For dissolved O2 determination, unaffected by other dissolved gases

·        Measuring range from 0.015 ppm to 45 ppm

·        Portable at-line use or as stand-alone version

Technical specifications

 

OxyQC Wide Range

Measuring range

O2

0.015 ppm to 45 ppm

Temperature

–3 °C to 40 °C (27 °F to 104 °F), acc. ±0.2 °C

Pressure

0 bar to 10 bar absolute (0 psi to 145 psi), acc. 0.01 bar

Repeatability s.d.

O2

±20 ppb (in range <5 ppm)

Resolution

1 ppb

Sample volume

>150 mL

Measuring units

ppm, ppb, hPa, mg/L, μg/L, % Air-sat., % O2-sat.

Measuring time

50 seconds

Data memory

500 measurement data sets

Built-in support

O2 Data Logger, threshold value functionality, system check

Portable use

Up to 11 hours continuous use

Communication interfaces

1x RS-232, 1x USB; optional: 1x RFID, 1x Bluetooth

Accessories

PFD (Plus), SFD, carrying strap, RFID tags, printer, rubber protection

Protection class

IP67

Dimensions (L x W x H)

262 mm x 209 mm x 176 mm (10.3 in x 8.2 in x 6.9 in)

Weight

1.7 kg (3.75 lbs)

Anton Paar- Xsample 610

Request Callback

Get Latest Price

Product Brochure
Model Name/NumberXsample 610
BrandAnton Paar
Usage/ApplicationIndustrial
Dimensions19.2 kg(42.3) excl. master instrument
Packaging Typecarton box
TypeHeated Sample Changer
Colorwhite

Anton Paar- Xsample 610

·        The single sample changer for heavy duty applications

·        Heats up samples up to 95 °C (200 °F) for easy filling

·        Ideal for crude oil, waxes, and gels

·        Automated cleaning and drying enables minimal operator handling

·        Compatible with most commercially available syringes


Xsample 610 is a heated single sample changer for the automated filling of highly viscous or even solid samples at room temperature. With its outstanding temperature range of up to 95 °C, the fastest measurement of crude oil, gels, and waxes is ensured in combination with density meters and viscometers from Anton Paar. Operators do not have to handle hot syringes to fill the sample into the measuring instrument. Automated cleaning and drying guarantee the best user experience.


Technical specifications

Max. sample viscosity

10,000 mPas at 95 °C

Max. temperature

95 °C (203 °F)

Filling mode

Syringe

Samples/hour

8

Sample volume

Approx. 3 mL

Magazine

No

Sample vials/packages

5 mL, 10 mL

Sample recovery

No

Dimensions LxWxH [mm (in)]

480 x 230 x 420 (18.9 x 9.1 x 16.5)
excl. master instrument

Weight [kg (lbs)]

19.2 (42.3) excl. master instrument

Master instruments

DMA 4100/4500/5000 M, SVM X001

Anton Paar- SmartPave 102e

Request Callback

₹ 300000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
Model Name/NumberSmartPave 102e
BrandAnton Paar
Size/Dimension444 x 678 x 586 mm
Weight42 kg

Minimum order quantity: 1 Piece

Technical specifications

Technical Data

Unit

SmartPave 102e

Bearing design

-

Air, fine-pored carbon

Motor design

-

Electronically Commutated (EC) - Permanent Magnet Synchronous Motor

Displacement transducer design

-

High-resolution optical encoder

Normal force measurment design
(US Pat. 6167752,1996)

-

360 ° capacitive sensor, non-contacting, fully integrated in bearing

Working mode

-

Combined Motor Transducer (CMT)

Minimum torque
(rotation)

nNm

5

 

Minimum torque
(oscillation)

nNm

2

 

Maximum torque

mNm

200

 

Minimum angular deflection
(set value)

µrad

0.5

 

Maximum angular deflection
(set value)

µrad

 

Minimum angular velocity

rad/s

0

 

Maximum angular velocity

rad/s

314

 

Maximum speed

1/min

3000

 

Minimum speed (CSS/CSR)

1/min

 10-7

 

Minimum angular frequency

rad/s

 10-7

 



Anton Paar-Autotap Single Station

Request Callback

₹ 3000 / Piece Get Latest Price

Product Brochure
BrandAnton Paar
Model Name/NumberAutotap Single Station
Usage/ApplicationIndustrial
Dimensions175 mm* x 540 mm x 280 mm
Packaging Typecarton box
weight11 kg

Anton Paar-Autotap Single Station

·        One automatically rotating tapping station

·        260 taps per minute

·        3 mm drop height


The Autotap and Dual Autotap tapped density analyzers for powders are simple-to-use, automated devices which comply with a large number of internationally recognized standard methods. They provide a high level of test method control with a user-selectable, lockable number of taps. Tapping rate and drop height are fixed to provide consistent results from sample to sample. A large range of sample sizes can be accommodated with the use of a number of different graduated cylinder sizes. 


Technical specifications

Specifications

Model

Autotap

 

Stations

1

 

Graduated cylinders

1 x 250 cm³

 

Graduated cylinder sizes

5 cm³ to 500 cm3 (standard)
1000 cm³ (with adapter plate)

Drop height

3 mm (0.125 in)

Tapping rate

260 per min.

Platform rotation

Automatic

Physical

Dimensions (H x W x D)

175 mm* x 540 mm x 280 mm (7 in* x 21 in x 11 in)
*excluding cylinders

Weight

11 kg (24 lbs)

 

Anton Paar-MCP 5500

Request Callback

₹ 34000 / Piece Get Latest Price

Product Brochure
Brandanton paar
Model Name/NumberMCP 5500
Measuring Range+-89.9 DegreeOR
Colorwhite
Resolution0.0001 DegreeOR

Minimum order quantity: 1 Piece

 Modular PolarimeterTop accuracy of <±0.0020° OR for highly traceable results
·        FillingCheck camera to monitor proper filling of sample along with air pump for sample cell drying
·        Up to eight different wavelengths (365 nm to 880 nm)
·        Full range of pharma features and data integrity solutions available
·        MCP desktop software included and plug-and-play connectivity to AP Connect


Technical specifications

Specifications                                                  MCP 5500

Measuring Scales

°Optical Rotation, °Optical Rotation (cell-length corrected), °Specific Rotation,°Specific Rotation (cell-length corrected), % concentration (g/100 mL, g/L, g/100 cm³, kg/m³), °International Sugar Scale (not temperature-compensated), mathematic functions, and user-definable scales

Measuring range

±89.9 °OR

 

Accuracy

<0.002 °OR across entire range

 

Repeatability

±0.001 °OR

 

Resolution

0.0001 °OR  

 

Available wavelenghts

589 nm standard
365, 405, 436, 546, 578, 633, 880 nm opt.

 

Temp. control range

Peltier temperature control
10 - 45 °C 

 

Temp. accuracy

±0.03 °C

 

Temp. control speed

2 °C sample temperature gradient eliminated in less than 30 seconds.
(100 mm stainless steel cell, re-filled with water)

 

21 CFR Part 11 compliance

yes

 

User Assistance Features

FillingCheck™ camera 

yes

 

Automatic detection of sample cell and quartz standard by Toolmaster™ function

yes
wireless Toolmaster™ technology

 


Anton Paar-MCP Sucromat 5300

Request Callback

Get Latest Price

Product Brochure
Usage/ApplicationIndustrial Use
Brandanton paar
Model Name/NumberMCP Sucromat 5300
Power consumption185 VA
Power managementPower-supply self-adapting to any mains voltage, 100 to 240 VAC, 50/60 Hz
weight33.5kg
Dimensions (L x W x H)797 mm x 437 mm x 231 mm

·        Accuracy of 0.01 °Z over the entire measuring range
·        LED light source with 100,000 h life time
·        Maintenance-free optical setup with robust construction
·        Multi-wavelength option for near infrared wavelength available  
·        Fully compliant to ICUMSA


Technical specifications

Measuring scales:

°Z at 589 nm

 

 

MCP 5300 Sucromat

 

Measuring range

± 259 °Z (± 89.9 °OR)

 

Resolution

0.001 °OR

 

Accuracy*

± 0.003 °OR
± 0.01 °Z

 

Repeatability

± 0.003 °OR
± 0.01 °Z"

 

Response time

12 seconds

 

Wavelength

589 nm and optionally 880 nm

Light source

LED light source with 100 000 hours lifetime

Sensitivity

Optical Density (OD) of 4.0, equivalent to OD 7.0 at 880 nm

Temperature control and measurement

Sensor

PT100 sensor for sample temperature measurement inside the cell or quartz control plate; wireless transfer to the instrument

Resolution

0.1 °C

 

Accuracy**

±0.1 °C

 

Temperature control range (Optional Peltier temperature control)

20 °C + 25 °C

Dimensions, power requirements, interfaces

Dimensions (L x W x H)

797 mm x 437 mm x 231 mm

Weight

33.5kg



* under physical standard conditions
** with Peltier module and Toolmaster sample cell (50/100/200 mm)

Anton Paar-MCP Sucromat 5500

Request Callback

Get Latest Price

Product Brochure
Usage/ApplicationIndustrial Use
Brandanton paar
Model Name/NumberMCP Sucromat 5500
Power consumption185 VA
Interfaces4 USB, RS232, Ethernet, VGA, CAN bus. Easy connection of keyboard, mouse, printer, bar code reader
Weight33.5kg
Dimensions (L x W x H)797 mm x 437 mm x 231 mm
·        Accuracy of 0.006 °Z over the entire measuring range
·        LED light source with 100,000 h life time
·        Maintenance-free optical setup with robust construction
·        Multi-wavelength option for near infrared wavelength available  
·        Fully compliant to ICUMSA


Technical specifications

Measuring scales:

°Z at 589 nm

 

MCP 5500 Sucromat

 

Measuring range

± 259 °Z (± 89.9 °OR)

 

Resolution

0.001 °OR

 

Accuracy*

< 0.002 °OR
< 0.006 °Z

 

Repeatability

< 0.001 °OR
< 0.003 °Z"

 

Response time

15 seconds

 

Wavelength

589 nm and optionally 880 nm

Light source

LED light source with 100 000 hours lifetime

Sensitivity

Optical Density (OD) of 4.0, equivalent to OD 7.0 at 880 nm

Temperature control and measurement

Sensor

PT100 sensor for sample temperature measurement inside the cell or quartz control plate; wireless transfer to the instrument

Resolution

0.1 °C

 

Accuracy**

±0.1 °C

 

Temperature control range (Optional Peltier temperature control)

20 °C + 25 °C

Dimensions, power requirements, interfaces

Dimensions (L x W x H)

797 mm x 437 mm x 231 mm

Weight

33.5kg

Power management

Power-supply self-adapting to any mains voltage, 100 to 240 VAC, 50/60 Hz


* under physical standard conditions
** with Peltier module and Toolmaster™ sample cell (50/100/200 mm)

Anton Paar- TRB V / THT V

Request Callback

Get Latest Price

Product Brochure
Model Name/NumberTRB V / THT V
Instrument TypeVacuum Tribometer
brandAnton Paar
featuresStable contact point and no parasitic friction

Anton Paar-TRB V / THT V

·        Testing compatible with DIN 50324, ASTM G99 and ASTM G133

·        Testing in liquids and controlled humidity

·        High-temperature model (max. 1000 °C)

·        For varied sample sizes and shapes

The vacuum tribometer is used to determine the sliding life of self-lubricating coatings as well as the friction and wear behavior of solid-state materials or hard coatings – with averaging time, contact pressure, velocity and temperature under vacuum conditions.
Anton Paar tribometers have proven their reliability worldwide in over 1,000 laboratories, for studying:

High-vacuum environments, down to 10e -7 mbar  
New materials (ceramics, metals, polymers)
Self-lubricating systems
Quality assurance

Key features Technical features:
  • Precisely calibrated friction and wear measurements
  • Stable contact point and no parasitic friction
  • Variable sample sizes and shapes
  • Automatic shut-off (max. track length / max. friction coefficient)
  • Testing in liquids and controlled humidity
  • Testing compatible with DIN 50324, ASTM G99 and ASTM G133
  • Powerful software package for PC
 Additional capabilities:
  • High temperature model (1000°C max temperature)
  • Range of ball/pin holders available
  • Contact depth measurement
  • High speed motor (1500 rpm)
  • Electrical contact resistance
Technical specifications

Rotation speed

Up to 600 rpm
(optional 1500 rpm)

Maximum torque

450 mNm

Friction force (LVDT sensor)

up to 10 N
(optional 20 N)

Maximum disk dimensions

Ø max. 55 mm;
Ø min 11mm;    
Thickness up to 10 mm

Maximum normal load

10 N
(optional 60 N)

Anton Paar-UTM Micro

Request Callback

Get Latest Price

Product Brochure
Model Name/NumberUTM Micro
Weight48 kg (58 with linear drive)
Brandanton paar
Maximum torque230
Dimensions444 x 753 x 586

·        Anton Paar-UTM Micro


Technical specifications

Force capacity

N

0.0005 to 40

Displacement

µm

0.01 to 9400 1)

Minimum torque

nNm

1

Maximum torque

mNm

230

Minimum angular deflection

µrad

0,05

Frequency (vertical)

Hz

0.001 to 100

Frequency (rotatory)

Hz

~10-8 to 100 2)

Temperature range

°C

-160 to 1000 3)

Heating rate (max)

K/min

up to 60

Cooling rate (max)

K/min

up to 50

Humidity

% rh

5 to 95

Dimensions

mm

444 x 753 x 586

Weight

kg

48 (58 with linear drive)

Drive system (rotation)

 

EC permanent magnet synchronous motor

Drive system (lift)

 

Moving magnet linear drive (lower drive) Stepper motor (upper drive)

Performs torsion, tensile, compression,
bending, shear, friction, peel, and other tests

 

✓

Customizable solutions

 

✓

Camera option

 

✓

 


1) In oscillation, a maximum displacement of ± 4500 μm.
2) Minimum frequency is a theoretical value (duration per cycle = 2 years).
3) In combination with CTD1000 and low-temperature option

Anton Paar-SurPASS 3 Eco

Request Callback

₹ 22000 / Piece Get Latest Price

Product Brochure
Model Name/NumberSurPASS 3 Eco
Weight24 kg
Packaging Typecarton box
brandanton paar
product typeElectrokinetic Analyzer for Solid Surface Analysis
dimensions600 mm x 432 mm x 245 mm (D x W x H)
Mains supplyAC 115 to 230 V, 50 to 60 Hz, 200 VA

Technical specifications

 

SurPASS 3 Eco

 

Measuring range

Streaming potential

±2000 mV ± (0.2 % + 4 μV)

Streaming current

±2 mA ± (0.2 % + 1 pA)

Cell resistance

5 Ω to 20 MΩ ± (2 % + 0.5 Ω)

Pressure measurement

1200 mbar ± (0.2 % + 0.5 mbar)

 

pH value

pH 2 to pH 12

Conductivity

0.1 mS/m to 1000 mS/m

Temperature

20 °C to 40 °C
Temperature control option is available

Sample size requirements

Porous films, foils, or plates

Rectangular-shaped: 20 mm x 10 mm (max. thickness: 2 mm )
Disk-shaped: 14 mm or 15 mm in diameter (max. thickness: 2 mm)

Non-porous films, foils, or plates

Rectangular-shaped: 20 mm x 10 mm (max. thickness: 2 mm) or
min. 35 mm x 15 mm (max. thickness: 40 mm)

Disk-shaped: 14 mm or 15 mm in diameter (max. thickness: 2 mm) or
min. 17 mm in diameter (max. thickness: 40 mm)

Particles

Particle size: min. 25 μm

Fibers

Min. 100 mg

Fabrics

Min. 30 mm x 30 mm

Hollow fiber membranes

Length: min. 170 mm

Ceramic membranes

Flat sheet: 14 mm in diameter
Single channel: outer diameter 10 mm or 13 mm
Multichannel: outer diameter 25 mm or 30 mm

Cylindrical cores

Height: max. 4 inch
Diameter: 1 inch

Flexible tubing

Length: min. 100 mm
Outer diameter: 0.7 mm to 6 mm

Pre-filled syringes

Syringe barrel “1.0 mL long” (ISO 11040-4)

Vials

2R/4R vials (ISO format), outer diameter 16 mm


Anton Paar-Envelope Density

Request Callback

₹ 100000 / Piece Get Latest Price

Model Name/NumberEnvelope Density
Brandanton paar
MaterialMild Steel
Usage/ApplicationIndustrial
TypeMCR Rheometer
FeaturesToolmaster automates adjustments, saves time and cuts errors

Anton Paar-Envelope Density

·        Envelope density setup from the leader in powder characterization

·        Buy an envelope density device and benefit from the full rheometer functionality

·        Budget-friendly option for envelope density determination

·        21 CFR Part 11 compliant

·        Automatic detection of setup to save time and eliminate errors

Anton Paar’s newly developed accessory for the measurement of envelope density and the porosity of solids is the most budget-friendly addition to an existing Anton Paar rheometer on the market. The setup facilitates the automated, standards-compliant analysis of powder flowability, improving production, transportation and storage processes, and saving time while eliminating manual errors with the Anton Paar patented Toolmaster feature.


Key features Envelope density and porosity from the leader in powder characterization

Acquire all the instruments you need from one supplier with expertise in powder material characterization and a reputation for excellent worldwide service and rapid delivery times.
Determine the porosity of your sample using Anton Paar’s Ultrapyc Series, the solid- and semi-solid density analyzers. Measure the skeletal density on top of the envelope density and calculate the porosity of your sample. 

More than just envelope density

Buy an envelope density device with a complimentary rheometer that facilitates powder flowability, and analyzes and improves production, transportation and storage processes. Not only that, but the unique modular concept of our MCR Evolution rheometers allows for DMA, tribology and mechanical testing, and, of course, classical rheology. 

One smart investment to accurately determine envelope density

Our unique MCR Evolution setup allows for the most budget-friendly addition to an existing rheometer for the measurement of envelope density. 

A pharma-compliant solution to determine envelope density

The RheoCompass software is 21 CFR Part 11 compliant, ensuring correct data storage and transparency for pharma customers.

Toolmaster automates adjustments, saves time and cuts errors

The automatic detection of measuring geometry and automatic adjustment of the required setting in RheoCompass via Toolmaster saves time and eliminates manual operator errors which might occur when manually changing the setup.

Anton Paar-Xsample 340

Request Callback

Get Latest Price

Product Brochure
Model Name/NumberXsample 340
BrandAnton Paar
Usage/ApplicationLaboratory
TypeSample Changer
Packaging Typecarton box
Colorgrey
Weight excl. master instrumentapprox. 9.4 kg
Dimensions excl. master instrument480 mm x 230 mm x 420 mm

Anton Paar-Xsample 340

·        The single sample changer for different syringe sizes

·        The robust solution for reliable and repeatable results

·        Prevents sample carry-over with automatic rinsing and drying after each sample

·        Highly resistant wetted parts for handling aggressive samples


Xsample 340 is a single sample changer for different types of syringes that automatically fills all Anton Paar master instruments using your favorite syringes. Perfect filling and excellent precision are facilitated by the system’s adjustable filling speed. Many years of trouble-free operation are guaranteed due to the straightforward and robust design. Xsample 340 is automatically prepared with up to two cleaning agents, ensuring perfect measuring conditions regardless of the operator and sample.


Technical specifications

Viscosity range

36,000 mPa·s at ambient and measuring temperature

Supported syringes

2 mL Luer plastic for sample viscosity up to 36,000 mPa·s
5 mL Luer plastic for sample viscosity up to 10,000 mPa·s
10 mL Luer plastic for sample viscosity up to 9,000 mPa·s
5 mL glass for sample viscosity up to 10,000 mPa·s

Filling mode

Force applied by syringe

Minimum sample volume per measurement

approx. 3 mL
depending on system configuration

Rinsing liquid consumption

approx. 7 mL (if rinse time: 10 s)
approx. 11 mL (if rinse time: 15 s)

Compressed air supply

0.3 bar (4.35 psi) relative (air supply of the master instrument)
max. 1.5 bar (21.8 psi) relative (air supply of Xsample 340)
optional: 2.0 bar (29 psi) relative (external compressed air)

Necessary quality of air

Class 3 from ISO 8573-1:
max. particle size: 5 μm
max. pressure dew point: –20°C (–4°F)
max. oil content: 1 mg/m3

Environmental conditions
(EN 61010)

Indoor use only

Air humidity

10 to 90% relative humidity, non-condensing

Operating temperature

+15 to +35 °C (+59 to +95 °F)

Power supply

supplied by master instrument
Mains voltage according to the type plate at the rear of master instrument (protective grounding required)

Dimensions excl. master instrument
(L x W x H)

480 mm x 230 mm x 420 mm
(18.9 in x 9.1 in x 16.5 in)

Weight excl. master instrument

approx. 9.4 kg (20.7 lbs)

X

Contact Us

Lakshmi (Director)
Instruhub
New No 3, Appaiar Lane, Royapuram
Chennai - 600013, Tamil Nadu, India

Get Directions
Send Email
Share: