Wholesaler of a wide range of products which include fluke 561 hvac infrared & contact thermometer and fluke 568 contact & infrared temp gun.
₹ 29000 / Piece Get Latest Price
| Brand | fluke |
| Model Name/Number | Fluke 561 HVAC Infrared & Contact Thermometer |
| Temperature | -40 to 550 DegreeC |
| Laser sighting | Single point laser |
| Power, battery life | 2 AA batteries (alkaline or NiCD) |
| Battery life | 12 hours |
| Operating temperature | 0 DegreeC to 50 DegreeC |
| Backlit display | Yes, LCD with dual temperatures, low battery, F/C indicator, and Scan/Hold options |
Minimum order quantity: 1 Piece
|
General Specifications |
|
|
Temperature |
-40 to 550°C (-40 to 1022°F) |
|
Display resolution |
0.1°C (0.1°F) of reading |
|
D:S (distance to spot size) |
12:1 |
|
Easy emissivity selector |
Adjustable with three settings: |
|
Low (0.3), medium (0.7). high (0.95) |
|
|
Display accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)] |
±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C / 32°F, ±1°C (±2°F) ±0.1°/1° |
|
Response time |
500 mSec (95% of reading) |
|
Repeatability |
±0.5% of reading or ±1°C (±2°F), whichever is greater |
|
Spectral response |
8 µm to 14 µm |
|
Laser sighting |
Single point laser |
|
Laser shutoff |
Laser turns off above ambient temperature of 40°C (104°F) |
|
Laser power |
Class 2(II) operation; Output < 1 mW, wavelength 630-670 nm |
|
Relative humidity |
10% to 90% RH non-condensing, at < 30°C (86°F) |
|
Power, battery life |
2 AA batteries (alkaline or NiCD) |
|
Battery life |
12 hours |
|
Display hold |
7 seconds |
|
Backlit display |
Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options |
|
Warranty |
2 years |
|
Operating temperature |
0°C to 50°C (32°F to 120°F) |
|
Storage temperature |
-20°C to 65°C (-25°F to 150°F) |
|
MAX, MIN, DIF temperatures |
Yes |
|
Thermocouple Type K mini adapter input |
Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range. |
|
Thermocouple Type K fabric hook-and-loop fastener pipe probe |
Yes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F) |
|
HVAC measurement guide |
Yes |
₹ 30000 / Piece Get Latest Price
| Brand | fluke |
| Model Name/Number | Fluke 568 Contact & Infrared Temp Gun |
| Infrared temperature range | -40 DegreeC to 800 DegreeC |
| Display | Dot matrix 98 x 96 pixels with function menus |
| Power | 2 AA/LR6 Batteries and USB when used with a PC |
| Operating temperature | 0 DegreeC to 50 DegreeC |
| Backlight | Two levels, normal and extra bright for darker environments |
| features | Offers a distance-to-spot ratio of 50:1 and Works with most K-type thermocouples |
Minimum order quantity: 1 Piece
|
Product Specifications |
||
|
Infrared temperature range |
-40°C to 800°C (-40°F to 1472°F) |
|
|
Infrared accuracy |
< 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); |
|
|
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater |
||
|
Display resolution |
0.1°C / 0.1°F |
|
|
Infrared spectral response |
8 µm to 14 µm |
|
|
Infrared response time |
< 500 msec |
|
|
Thermocouple Type-K input temperature range |
-270°C to 1372°C (-454°F to 2501°F) |
|
|
Thermocouple Type-K input accuracy |
-270°C to -40°C |
±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F)) |
|
-40°C to 1372°C |
±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater |
|
|
D:S (distance to measurement spot size) |
50:1 |
|
|
Laser sighting |
Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm |
|
|
Minimum spot size |
19 mm (0.75 in) |
|
|
Emissivity adjustment |
By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
|
|
Data storage with date/time stamp |
99 points |
|
|
PC interface and cable |
USB 2.0 with FlukeView® Forms software |
|
|
Hi/Low alarms |
Audible and two-color visual |
|
|
Min/Max/Avg/Dif |
Yes |
|
|
Display |
Dot matrix 98 x 96 pixels with function menus |
|
|
Backlight |
Two levels, normal and extra bright for darker environments |
|
|
Trigger lock |
Yes |
|
|
Switchable Celsius and Fahrenheit |
Yes |
|
|
Power |
2 AA/LR6 Batteries and USB when used with a PC |
|
|
Battery life |
If used continuously |
Laser and backlight on,12 hours; laser and backlight off, 100 hours |
|
|
||
Lakshmi (Director)
Instruhub
New No 3, Appaiar Lane, Royapuram
Chennai - 600013, Tamil Nadu, India