Providing you the best range of cc-05 multi functional calibrator, fluke 718 pressure calibrator, fluke 754 documenting process calibrator-hart, fluke 725 multifunction process calibrator and fluke 725ex series process calibrator with effective & timely delivery.
₹ 22000 / Piece Get Latest Price
| Accuracy | 0.02% |
| Model Name/Number | CC-05 |
| Display Type | Digital |
| Usage/Application | Industrial |
| Type | Rechargeable Battery |
| Power Source | 3.7V |
Minimum order quantity: 1 Piece
| Signal | Range | Precision | Resolution | Impedance |
|---|---|---|---|---|
| Current (mA) | 0~24mA | ± (0.02%+0.003) | 0.001mA | 100Ω |
| Voltage (V) | 0~24V | ± (0.02%+0.003) | 0.001V | 500K |
| Passive (XMT) | 0~24mA | ± (0.02%+0.003) | 0.001mA | 100Ω |
| 24V loop | 0~24mA | ± (0.1%+0.005) | 0.00mA | 100Ω |
| FRQ (Hz) | 0~9999Hz | ± 2% | 5digit | 1MK |
| mV | -10~100mV | ± (0.03%+0.003) | 0.01mV | 2K |
| TC (TC-S | 0~1760ºC | ± (0.2%+1) | 1ºC | 2K |
| TC (TC-B) | 0~1810ºC | ± (0.5%+1) | 1ºC | 2K |
| TC (TC-E) | 0~990ºC | ± (0.2%+1) | 1ºC | 2K |
| TC (TC-K) | 0~1320ºC | ± (0.2%+1) | 1ºC | 2K |
| TC (TC-R) | 0~1760ºC | ± (0.3%+1) | 1ºC | 2K |
| TC (TC-J) | 0~1190ºC | ± (0.3%+1) | 1ºC | 2K |
| TC (TC-T) | 0~390ºC | ± (0.2%+1) | 1ºC | 2K |
| TC (TC-N) | 0~1290ºC | ± (0.2%+1) | 1ºC | 2K |
| TC (WRe3/25) | 0~2320ºC | ± (0.2%+1) | 1ºC | 2K |
| TC (WRe3/26) | 0~2320ºC | ± (0.2%+1) | 1ºC | 2K |
| RES (ohm) | 0~390Ω | ± (0.2%+1) | 0.1Ω | / |
| Pt100 | -200~650ºC | ± (0.5%+1) | 0.1ºC | / |
| Cu50 | -20~150ºC | ± (0.5%+1) | 0.1ºC | / |
₹ 30000 / Piece Get Latest Price
| Model Name/Number | Fluke 718 Pressure Calibrator |
| Display Type | lcd |
| Usage/Application | Industrial |
| Type | process tools |
| Maximum voltage | 30 volts |
| Operating temperature | -10 DegreeC to 55 DegreeC |
| Size | 216 x 94 x 66 mm |
| Weight | 992 g |
| Power, battery life | 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 |
Minimum order quantity: 1 Piece
|
Technical Specifications |
|
|
Fluke 718 Series |
|
|
Measure pressure |
(Internal sensor) |
|
Accuracy |
0.025% full scale |
|
Functions |
Zero, min/max, hold, damp |
|
Dry air, non-corrosives only |
|
|
Fluke 718 1G |
|
|
Range |
-1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa) |
|
Resolution |
0.0001 psi, 0.001 mbar, 0.0001 kPa |
|
Over pressure |
5x Full Scale |
|
Functions |
Zero, Min, Max, Hold, Damp |
|
|
|
|
|
|
|
|
|
|
General Specifications |
|
|
Maximum voltage |
30 volts (non-operating) |
|
Temperature |
-40°C to 60°C |
|
Operating temperature |
-10°C to 55°C |
|
Relative humidity |
95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C) |
|
Operating altitude |
3,000 M max |
|
Shock |
1 M drop test |
|
Vibration |
Random, 2 g, 5 Hz – 500 Hz |
|
Safety |
CSA C22.2 No. 1010.1: 1992 |
|
EMC |
EN50082-1: 1992 and EN55022: 1994 Class B |
|
Size |
216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in) |
|
Weight |
992 g (35 oz) |
|
Power, battery life |
9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 |
|
Battery life |
4 to 20 hours typical, depending on functions used |
|
Warranty |
Three years (one year on pressure pump in Fluke 718) |
|
Display |
LCD, 5 digit pressure and current simultaneous |
₹ 38000 / Piece Get Latest Price
| Model Name/Number | Fluke 754 Documenting Process Calibrator-HART |
| Brand | Fluke |
| Type | process tools |
| Usage/Application | process calibrator |
| Weight | 1.2 kg |
| Size | 136 x 245 x 63 mm |
| Operating temperature | -10 DegreeC to +50 DegreeC |
| Operating altitude | 3000 m above mean sea level (9842 ft) |
| Batteries | Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh |
Minimum order quantity: 1 Piece
|
Technical Data |
|||
|
Data log functions |
Measure functions |
Voltage, current, resistance, frequency, temperature, pressure |
|
|
Reading rate |
1, 2, 5, 10, 20, 30, or 60 readings/minute |
||
|
Maximum record length |
8000 readings (7980 for 30 or 60 readings/minute) |
||
|
Ramp functions |
Source functions |
Voltage, current, resistance, frequency, temperature |
|
|
Rate |
4 steps/second |
||
|
Trip detect |
Continuity or voltage (continuity detection not available when sourcing current) |
||
|
Loop power function |
Voltage |
Selectable, 26 V |
|
|
Accuracy |
10%, 18 V minimum at 22 mA |
||
|
Maximum current |
25 mA, short circuit protected |
||
|
Maximum input voltage |
50 V DC |
||
|
Step functions |
Source functions |
Voltage, current, resistance, frequency, temperature |
|
|
Manual step |
Selectable step, change with arrow buttons |
||
|
Autostep |
Fully programmable for function, start delay, stepvalue, time per step, repeat |
||
|
Environmental Specifications |
|||
|
Operating temperature |
-10°C to +50°C |
||
|
Storage temperature |
-20°C to +60°C |
||
|
Dust/water resistance |
Meets IP52, IEC 529 |
||
|
Operating altitude |
3000 m above mean sea level (9842 ft) |
||
|
Safety Specifications |
|||
|
Agency approvals |
CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 |
||
|
Mechanical and General Specifications |
|||
|
Size |
136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) |
||
|
Weight |
1.2 kg (2.7 lb) |
||
₹ 30000 / Piece Get Latest Price
| Model Name/Number | Fluke 725 Multifunction Process Calibrator |
| Display Type | Digital |
| Type | process tools |
| Operating temperature | -10 DegreeC to +55 DegreeC |
| Operating altitude | 3000 m |
| Size | 130 x 236 x 61 mm |
| Weight | 0.65 kg |
| Batteries | 4 AA alkaline batteries |
Minimum order quantity: 1 Piece
|
Measurement Accuracy |
||||
|
Voltage DC |
30.000 V |
0.02% + 2 counts (upper display) |
||
|
30.000 V |
0.02% + 2 counts (lower display) |
|||
|
100.00 mV |
0.02% + 2 counts |
|||
|
-10.00 mV to 75.00 mV |
0.025% + 1 count (via TC connector) |
|||
|
Current DC |
24.000 mA |
0.02% + 2 counts |
||
|
Resistance |
0.0 to 400.0 Ω |
0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
||
|
401 to 1500 Ω |
0.5 Ω (4-wire), 1 Ω (2- and 3-wire) |
|||
|
1500 to 3200 Ω |
1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
|||
|
Frequency |
2.0 to 1000.0 CPM |
0.05% + 1 count |
||
|
1.0 to 1100.0 Hz |
0.05% + 1 count |
|||
|
1.00 to 10.00 kHz |
0.05% + 1 count |
|||
|
Sensitivity |
1 V peak-to-peak-minimum |
|||
|
Environmental Specifications |
||||
|
Operating temperature |
-10°C to +55°C |
|||
|
Storage temperature |
-20°C to 71°C |
|||
|
Operating altitude |
3000 m |
|||
|
Safety Specifications |
||||
|
Agency approvals |
EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 |
|||
|
Mechanical and General Specifications |
||||
|
Size |
130 x 236 x 61 mm |
|||
|
Weight |
0.65 kg |
|||
|
Batteries |
4 AA alkaline batteries |
|||
|
Battery replacement |
Separate battery compartment, accessable without breaking calibration seal |
|||
|
Side port connections |
Pressure module connector, also used for remote real-time programming |
|||
₹ 30000 / Piece Get Latest Price
| Model Name/Number | Fluke 725Ex Series Process Calibrator |
| Type | process tools |
| Brand | Fluke |
| Weight | 0.85 kg |
| Size | 130 x 236 x 61 mm |
| I Deal In | New Only |
| Batteries | 4 AA alkaline batteries |
Minimum order quantity: 1 Piece
|
Measurement Accuracy |
||||
|
Voltage DC |
30.000 V |
0.02% + 2 counts (upper display) |
||
|
10.000 V |
0.02% + 2 counts (lower display) |
|||
|
90.00 mV |
0.02% + 2 counts |
|||
|
-10.00 mV to 75.00 mV |
0.025% + 1 count (via TC connector) |
|||
|
Current DC |
24.000 mA |
0.02% + 2 counts |
||
|
Resistance |
0.0 to 400.0 Ω |
0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) |
||
|
401 to 1500 Ω |
0.5 Ω (4-wire), 1 Ω (2- and 3-wire) |
|||
|
1500 to 3200 Ω |
1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
|||
|
Frequency |
2.0 to 1000.0 CPM |
0.05% + 1 count |
||
|
1.0 to 1100.0 Hz |
0.05% + 1 count |
|||
|
1.00 to 10.00 kHz |
0.05% + 1 count |
|||
|
Sensitivity |
1 V peak-to-peak-minimum |
|||
|
Pressure |
Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
|||
|
Source Accuracy |
||||
|
Voltage DC |
100.00 mV |
0.02% + 2 counts |
||
|
10.000 V |
0.02% + 2 counts |
|||
|
-10.00 mV to 75.00 mV |
0.025% + 1 count (via TC connector) |
|||
|
Current DC |
24.000 mA (source) |
0.02% + 2 counts |
||
|
24.000 mA (simulate) |
0.02% + 2 counts |
|||
|
Resistance |
15.0 to 400.0 Ω |
0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) |
||
|
|
||||
Lakshmi (Director)
Instruhub
New No 3, Appaiar Lane, Royapuram
Chennai - 600013, Tamil Nadu, India