Offering you a complete choice of products which include fluke 719pro electric pressure calibrator, fluke 729 automatic pressure calibrator, fluke calibration p5514b hydraulic pressure comparator, fluke 730g digital pressure calibrator, thermofisher scientific-antaris mx ft-nir process analyzer and fluke 721 pressure calibration instruments.
₹ 29000 / Piece Get Latest Price
| Model Name/Number | Fluke 719Pro Electric Pressure Calibrator |
| Usage/Application | Industrial |
| Type | process tools |
| Weight Kg | With holster 1.2 kg |
| Operating temperature | -10 DegreeC to +50 DegreeC |
| Battery | Eight (8) standard Alkaline AA batteries |
| Battery life | 300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum |
| Dimensions | 24.13 x 11.18 x 7 cm |
Minimum order quantity: 1 Piece
|
Measurement |
|||
|
Fluke-719Pro-30G |
Range |
-12 to 30 psi / -0.8 to 2 bar |
|
|
Resolution |
0.001 psi / 0.0001 bar |
||
|
Fluke-719Pro-150G |
Range |
-12 to 150 psi / -0.8 to 10 bar |
|
|
Resolution |
0.01 psi / 0.001 bar |
||
|
Fluke-719Pro-300G |
Range |
-12 to 300 psi / -0.8 to 20 bar |
|
|
Resolution |
0.01 psi / 0.001 bar |
||
|
Accuracy |
±0.025% of full scale, 6 months |
||
|
Temperature effect (all ranges) |
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
||
|
Dry air and non-corrosive gas only |
|||
|
Function |
Range |
Resolution |
Accuracy (1 year) |
|
mA DC (simulation and measurement) |
0-24 mA DC |
0.001 mA |
±0.015% of reading ±2 counts |
|
1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate |
|||
|
Volts DC (measurement only) |
30 V DC |
0.001 V |
±0.015% of reading ±2 counts |
|
No AC voltage measurement, do not exceed 30 V DC |
|||
|
Temperature (measurement only, Pt100 RTD) |
-50 to 150°C |
0.01°C |
Temperature ±0.1°C (0.2°F) |
|
±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory) |
|||
|
Loop power supply |
24 V DC |
N/A |
24 mA at 24 V |
|
Temperature effect (all functions) |
- |
- |
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
|
No effect on accuracy on all functions from 15°C to 35°C |
|||
₹ 28000 / Piece Get Latest Price
| Model Name/Number | Fluke 729 Automatic Pressure Calibrator |
| Usage/Application | Industrial |
| Type | process tools |
| Size | 7 x 27.94 x 17.27 cm |
| Weight | 2.95 kg |
| Operating temperature | -10 DegreeC to 50 DegreeC for measurement, 0 DegreeC to 50 DegreeC for pressure control |
| Operating temperature with battery | -10 DegreeC to 40 DegreeC |
| Operating altitude | 3000 m |
Minimum order quantity: 1 Piece
|
Electrical specification |
|
|
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range. |
|
|
Ranges |
|
|
mA measure, source and simulate |
0 mA to 24 mA |
|
Volts dc measure |
0 V dc to 30 V dc |
|
Resolution |
|
|
mA dc source, simulate and measure |
1 μA |
|
Voltage dc measurement |
1 mV |
|
Accuracy |
0.01% ±2 LSD all ranges (at 23 °C ±5 °C) |
|
Stability |
20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C |
|
mA simulate external voltage requirement |
12 V dc to 30 V dc |
|
Loop compliance voltage |
24 V dc @ 20 mA |
|
mA simulate external voltage requirement |
12 V dc to 30 V dc |
|
Temperature measurement only/100 Ω Pt(385) RTD |
-50 °C to 150 °C (-58 °F to 302 °F) |
|
Temperature resolution |
0.01 °C (0.01 °F) |
|
Temperature accuracy |
±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory) |
|
Drive capability |
1200 Ω without HART resistor, 950 Ω with internal HART resistor |
|
Mechanical specification |
|
|
Size (HxWxL) |
7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in) |
|
Weight |
6.5 lbs., 2.95 kg |
|
Ingress protection |
IP54 |
|
Environmental specification |
|
|
Operating temperature |
-10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control |
|
|
|
₹ 40000 / Piece Get Latest Price
| Model Name/Number | Fluke Calibration P5514B Hydraulic Pressure Comparator |
| Usage/Application | Industrial |
| brand | fluke |
| features | Easily generate pressure to 10 000 psi (70 MPa) |
| Pressure Range | 0 to 10,000 psi (700 bar) |
| Instrument Size | 11 x 11 x 10 in (280 x 280 x 254 mm) |
| Instrument Weight | 5 kg |
| Reservoir Volume | 75 cc |
Minimum order quantity: 1 Piece
Product overview:
The P5514B Hydraulic Pressure Comparator is a simple, robust and economical pressure comparison test pump for calibrating gauges, switches and transducers with precise, fine adjust capabilities. It generates pressure to 10 000 psi (70 MPa), with a new Vernier fine-adjustment control that enables cardinal point calibrations. The P5514B can be mounted easily on a bench or used in mobile applications. Its robust design, with improved reservoir valve sealing, makes it a more stable pressure generator than previous versions of this model. Test port connections include adapters for common sizes of NPT and BSP. Connections are tool free, no sealing tape required, another design improvement which, coupled with the new Vernier fine adjustment control, simplifies and improves pressure testing.
Specifications:|
Pressure Range |
0 to 10,000 psi (700 bar) |
|
Test Port Adapters |
1/4 NPT (Qty 2), 1 each of 1/2 NPT, 1/4 BSP and 1/2 BSP |
|
Instrument Size (W x D x H) |
11 x 11 x 10 in (280 x 280 x 254 mm) |
|
Instrument Weight |
11 lb (5 kg) |
|
Reservoir Volume |
75 cc |
|
Screw Press Displacement |
20 cc |
|
Fluid media |
The standard O-ring seals are Viton®. Ethylene Propylene seals are available for use with solvents, fuel oils, brake fluids or other similar aggressive fluids. |
₹ 30000 / Piece Get Latest Price
| Model Name/Number | Fluke 730G Digital Pressure Calibrator |
| Type | process tools |
| features | Storage up to 128 sets of calibration data |
| usage | Paperless testing and reporting |
| Current | 0 mA to 24 mA |
| Current range | 1 A |
| Voltage range | 1 mV |
Minimum order quantity: 1 Piece
Product overview:
A compact, smart pressure solution for bench or field
The Fluke 730G Smart Digital Pressure Calibrator combines the performance of a precision test gauge with the power of a loop calibrator and also includes internal HART communication capabilities. When used with a pressure test pump the Fluke 730G becomes a high-efficiency, highly accurate calibrator that can test pressure gauges, pressure switches and pressure transmitters making it ideal for instrument shops, gauge labs and pressure laboratories.
Built-in HART Communication: The integrated HART communication functionality is easy-to-use and allows you to adjust HART directly, without requiring additional tools for adjustment.
Precision Pressure and Current Measurements: The 730G series provides high-precision 0.02% pressure measurement accuracy and 0.01% current measurement accuracy to meet the requirements for establishing a pressure laboratory and achieving accurate pressure calibration results.
Intuitive operation and ease of use: A high-end LCD display and dual-jack design bring a more convenient and efficient user experience.
Paperless testing and reporting: Optional 730G/PCSW management software enables paperless testing giving you the ability to automatically generate test reports and document results.
Electrical specifications (All specifications are valid to 110% of range)
Current 0 mA to 24 mA
Voltage 0 V DC to 30 V DC
Current range 1 μA
Voltage range 1 mV
Accuracy 0.01% ± 2 LSD all ranges @ 23°C ±5 °C
Temperature compensation From 20% FS/°C @ -10 °C to +18 °C and 28 °C to 50 °C
Loop Compliance Voltage 24 V DC @ 20 mA
Temperature measurement accuracy inside the product ±0.5 ℃
Drive Capability 1200 Ω (without HART resistor), 950 Ω (with internal HART resistor)
₹ 100000 / Piece Get Latest Price
| Model Name/Number | Antaris MX FT-NIR Process Analyzer |
| Weight | 25.8 kg |
| Voltage | 90/264 V |
| Detection | High sensitivity, high stability matched InGaAs |
| Height | 48.2 x 40.6 x 24.7 cm |
| Operating Temperature Range | 15 DegreeC to 35 DegreeC |
| Sampling Mode | Fiber optic multiplexing |
| Sealed and Desiccated | yes |
Minimum order quantity: 1 Piece
This easy-to-use NIR analyzer allows a single process to be monitored at multiple points or multiple processes to be monitored simultaneously. The Antaris MX Process Analyzer also eliminates removing the probe from the process stream for background collection or qualification.
The Antaris MX FT-NIR Process Analyzer Features:
Recommended for:
Description Antaris MX FT-NIR Process Analyzer
Analyzer Type Fourier Transform Near-Infrared
Detection High sensitivity, high stability matched InGaAs
Height (English) 18.97 x 15.98 x 9.72 in.
Height (Metric) 48.2 x 40.6 x 24.7 cm
Interface Direct PC to ethernet allows file system and OPC communications
Interferometer Proven, frictionless, stable, long-life Michelson
Operating Temperature Range 15°C to 35°C (59° to 95°F)
Photometric Linearity Slope 1.0 ±0.05 and an intercept of 0.0 ±0.05
Resolution 4 cm-1 across spectral range (0.6 nm at 1250 nm), 2 cm-1 option across spectral range (0.3 nm at 1250 nm)
Sampling Mode Fiber optic multiplexing
Sealed and Desiccated Yes
Source Type Long-life, high-intensity halogen NIR source; spare source included with system, guaranteed filament image alignment
Spectral Range 12,000 to 3800 cmto1 (833 to 2500 nm)
System Status Indicators Indicator lights report scan, laser, power, and source status continuously
Voltage 90/264 V
Wavenumber Accuracy ±0.1 cm-1 (0.02 nm at 1250 nm)
Wavenumber Repeatability (System to System) Better than 0.05 cm-1 (0.008 at 1250 nm)
Wavenumber Reproducibility (Single System) 10 measurement standard deviation <0.006cm-1
Weight (English) 105.16 lb.
Weight (Metric) 25.8 kg
Unit Size Each
₹ 36000 / Sample Get Latest Price
| features | Measures 4 to 20 mA signals |
| Operating temperature | 10 DegreeC to +50 DegreeC |
| Altitude | 2,000 m |
| Batteries required | (4) Standard AA cells |
| Dimensions | 7.9 x 4.3 x 2.3 in |
| Weight | 03539 kg |
Minimum order quantity: 1 Sample
|
General Specifications |
||||
|
Instrument setup recall |
Last used on power-up |
|||
|
Environmental |
Operating temperature -10°C to +50°C |
|||
|
Altitude |
2,000 m |
|||
|
Ingress protection |
IP-40 |
|||
|
Power requirements |
6.0 V DC |
|||
|
Battery life |
>35 hours, typical usage |
|||
|
Batteries required |
(4) Standard AA cells |
|||
|
Dimensions (H x W x D) |
7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm) |
|||
|
Weight |
03539 kg (1 lb 3 oz) |
|||
|
Connectors/ports pressure |
Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe |
|||
|
Electrical and Temperature Measurement 1-Year |
||||
|
Function |
Range |
Resolution |
Accuracy |
|
|
mA measure |
0 to 24 mA |
0.001 mA |
±0.015% of rdg |
|
|
V DC measure |
0 to 30 V DC |
0.001 V |
±0.015% of rdg |
|
|
Temperature measure (RTD/ Ohms)1 |
-40°C to 150°C |
0.01°C, 0.01°F |
±0.015% of rdg |
|
|
Loop power supply |
24 V |
N/A |
24 mA @ 24 V |
|
|
Temperature Effect |
||||
|
No effect on accuracy on all functions from 15°C to 35°C |
||||
|
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
||||
|
|
||||
₹ 29000 / Sample Get Latest Price
| model | Fluke 700G Pressure Gauge Calibrator |
| features | Precision pressure gauge calibrators designed for fast, accurate test results |
| usage | Make precise pressure measurements from +-10 inH2O/20 mbar to 10,000 psi/690 bar |
| Dimensions | 12.7 x 11.4 x 3.7 cm |
| Power | Three (3) AA alkaline batteries |
| Battery life | 1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate |
Minimum order quantity: 1 Sample
Specifications:
|
Model |
Range |
Resolution |
Accuracy |
Burst Pressure |
|
Fluke-700G01 |
-10 to +10 inH2O |
0.001 inH2O, |
Positive pressure ±0.1% of range, |
3 psi, |
|
Fluke-700G02 |
-1 to +1 psi, |
0.0001 psi, |
Positive pressure ±0.1% of range, |
5 psi, |
|
Fluke-700G04 |
-14 to 15 psi, |
0.001 psi, |
Positive pressure ±0.05% FS |
60 psi, |
|
Fluke-700G05 |
-14 to 30 psi, |
0.001 psi, |
Positive pressure ±0.05% FS |
120 psi, |
|
Fluke-700G06 |
-12 to 100 psi, |
0.01 psi, |
Positive pressure ±0.05% FS |
400 psi, |
|
Fluke-700G27 |
-12 to 300 psi, |
0.01 psi, |
Positive pressure ±0.05% FS |
1200 psi, |
|
Fluke-700G07 |
-12 to 500 psi, |
0.01 psi, |
Positive pressure ±0.05% FS |
2000 psi, |
|
Fluke-700G08 |
-14 to 1000 psi, |
0.1 psi, |
Positive pressure ±0.05% FS |
4000 psi, |
|
Fluke-700G10 |
-14 to 2000 psi, |
0.1 psi, |
Positive pressure ±0.05% FS |
8000 psi, |
|
Mechanical Specifications |
|
|
Dimensions (H x W x D) |
12.7 x 11.4 x 3.7 cm (5 x 4.5 x 1.5 in) |
|
Pressure connection |
¼ in NPT Male |
|
Housing/Weight |
Cast ZNAL 0.56 kg (1.22 lb) with holster |
|
Display |
5-1/2 digits, 16.53 mm (0.65 in) high 20-segment bar graph, 0 to 100% |
|
Power |
Three (3) AA alkaline batteries |
|
Battery life |
1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate |
Lakshmi (Director)
Instruhub
New No 3, Appaiar Lane, Royapuram
Chennai - 600013, Tamil Nadu, India