Wholesaler of a wide range of products which include anton paar rotational viscometer: viscoqc100 r, anton paar rotational viscometer:viscoqc100 h, byk instruments- rotational viscometer, premium models, anton paar-ultrapyc 5000 foam, anton paar- frs 1800 and datacolor-spectravision : precise color evaluation of nearly anything.
₹ 100000 / Piece Get Latest Price
| Number Of Cups | 2 |
| Model Name/Number | ViscoQC 100 R |
| Brand | ANTON PAAR |
| Viscosity | 6.4 mPa.s to 40,000,000 mPa.s |
| Material | Steel |
| Usage/Application | Laboratory |
| Features | Full traceability for reliable viscosity tests |
| Compatible measuring system | 6 RH spindles to measure medium-viscosity samples |
| Measurement Repeatability | +-0.2 % |
| Rotate Speed | 0.1 rpm to 200 rpm 740 increments |
| Rotational speed | 0.1 rpm to 200 rpm 740 increments |
ViscoQC 100 R
KEY FEATURES:
The easiest way to measure dynamic viscosityYou don’t need to be an expert to measure with ViscoQC. Anton Paar’s viscometers guide you from start-up through the entire measurement process via an intuitive user interface. Continue to use the standard operating procedure methods of your existing rotational viscometer: ViscoQC uses the same instrument setup and measuring settings to deliver the same results. Each spindle is equipped with magnetic coupling for easy spindle exchange, saving you up to 15 seconds per test. The coupling also reduces maintenance costs by protecting the spindle and instrument against damage caused by knocks or bending. All spindles from Anton Paar are made of chemically resistant stainless steel (AISI 316L), which increases spindle lifetime by protecting them from corrosion.
Standards Applicable
ASTM D115 , ASTM D789, ASTM D1076, ASTM D1084, ASTM D1337, ASTM D1338, ASTM D1417, ASTM D1439, ASTM D1824,
ASTM D2196, ASTM D2243, ASTM D2364, ASTM D2556, ASTM D3288, ASTM D3468, ASTM D3716, ASTM D3730, ASTM D3794
ASTM D4016, ASTM D4143, ASTM D4300, ASTM D4878, ASTM D4889, ASTM D5324, ASTM D5400, ASTM D6279, ASTM D6577
ASTM D7394, ASTM D8020, E2975, E3070, E3116, F1607, F3208
BS5350
Chinese Pharmacopoeia (ChP) - 0633 Rotational viscosity measurement method, method IIIDIN 2555, DIN 3219, DIN 16945, DIN 52007-1, DIN 53019-1, DIN 54453
EN 302-7, EN 2555, EN 3219, EN 10301, EN 12092, EN 12802, EN 15425, EN 15564,
ISO 1652
ISO 2535
ISO 2555
ISO 3219
ISO 10364-12
Japanese Pharmacopoeia (JP) - XVII 2.53 (2.1.2) Single cylinder-type rotational viscometer Pharmacopoeia Europe (Ph. Eur.) - 2.2.10 - Rotating viscometer methodTAPPI - T648
TAPPI - T697
TECHNICAL SPECIFICATION
|
|
ViscoQC 100 |
|
|
R |
|
Viscosity test |
Single-point |
|
Viscosity range [mPa.s or cP] |
0.2* to 6 M |
|
SpeeASTM D [rpm] |
0.1 rpm to 200 rpm |
|
Max. spring torque [mNm] |
0.7187 |
|
Accuracy |
±1.0 % full scale range |
|
Repeatability |
±0.2 % |
|
Heli-Plus compatibility |
✔ |
|
PTASTM D 100 Cone-Plate compatibility |
✔ |
|
Peltier temperature control |
15 °C to 80 °C 0 °C to + 100 °C |
|
LiquiASTM D temperature control/sensing |
Ambient to +100 °C (control of L/RH spinASTM Dles with optional thermostat bath) |
|
|
₹ 464000 / Piece Get Latest Price
| Model Name/Number | ViscoQC 100 H |
| Brand | anton paar |
| Viscosity | 51.2 mPa.s to 320,000,000 mPa.s |
| Material | Steel |
| Usage/Application | Laboratory |
| Number Of Cups | 2 |
| Type | Rotational viscometer |
| Maximum Viscosity Range | 13.2*** to 320 M |
| Features | The easiest way to measure dynamic viscosity |
| Viscocity Rpm | 0.1 rpm to 200 rpm 740 increments |
| Ambient Temperature | -60 DegreeC to +300 DegreeC (temperature sensing with optional Pt100) |
| Measurement Repeatability | +-0.2 % |
| Rotate Speed | 0.1 rpm to 200 rpm 740 increments |
| Measurement Precision | +-1.0 % full scale range |
Minimum order quantity: 1 Piece
KEY FEATURES:
ViscoQC instantly detects and documents the measuring setup of the following parts:
To ensure correct viscosity results, all spindle data is automatically delivered to the viscometer as soon as the spindle is attached. With ViscoQC 300, Toolmaster™ further restricts each method to a unique spindle identity. No time is wasted with repeat measurements (e.g., if the wrong spindle is mistakenly chosen from the spindle list). If you need to measure new formulations, ViscoQC automatically leads you to the right spindle/speed configuration using TruMode™.
Standards Applicable
ASTM D115 , ASTM D789, ASTM D1076, ASTM D1084, ASTM D1337, ASTM D1338, ASTM D1417, ASTM D1439, ASTM D1824,
ASTM D2196, ASTM D2243, ASTM D2364, ASTM D2556, ASTM D3288, ASTM D3468, ASTM D3716, ASTM D3730, ASTM D3794
ASTM D4016, ASTM D4143, ASTM D4300, ASTM D4878, ASTM D4889, ASTM D5324, ASTM D5400, ASTM D6279, ASTM D6577
ASTM D7394, ASTM D8020, E2975, E3070, E3116, F1607, F3208
BS5350
Chinese Pharmacopoeia (ChP) - 0633 Rotational viscosity measurement method, method III
DIN 2555, DIN 3219, DIN 16945, DIN 52007-1, DIN 53019-1, DIN 54453
EN 302-7, EN 2555, EN 3219, EN 10301, EN 12092, EN 12802, EN 15425, EN 15564,
ISO 1652
ISO 2535
ISO 2555
ISO 3219
ISO 10364-12
Japanese Pharmacopoeia (JP) - XVII 2.53 (2.1.2) Single cylinder-type rotational viscometerPharmacopoeia Europe (Ph. Eur.) - 2.2.10 - Rotating viscometer method
TAPPI - T648
TAPPI - T697
TECHNICAL SPECIFICATION
|
|
ViscoQC 100 |
|
|
H |
|
Viscosity test |
Single-point |
|
Viscosity range [mPa.s or cP] |
1.3** to 40 M |
|
SpeeASTM D [rpm] |
0.1 rpm to 200 rpm |
|
Max. spring torque [mNm] |
0.7187 |
|
Accuracy |
±1.0 % full scale range |
|
Repeatability |
±0.2 % |
|
Heli-Plus compatibility |
✔ |
|
PTASTM D 100 Cone-Plate compatibility |
✔ |
|
Peltier temperature control |
15 °C to 80 °C 0 °C to + 100 °C |
₹ 50000 / Piece Get Latest Price
| Weight | 6.5 kg |
| Power Supply | Worldwide power supply, 24v voltage DC input / Separate 24 VDC power supply |
| Viscosity Range | 4 - 6000000 cP |
| No. of Spindles | 4 |
| Repeatability | 0.2% |
| Accuracy | 1.0% full scale range |
| Languages | English German French Italian Spanish Russian Japanese Chinese |
| Dimensions: L x W x H | 25 x 31 x 47 cm |
Minimum order quantity: 1 Piece
Rotational Viscometer, Premium Models:
byko-visc RT L
Rotational Viscometer - premium model for low viscosity-
Features:
As a manufacturer, viscosity specifications need to be developed and defined by R&D for the products used in specific conditions – often customization of recipes is required. To ensure a stable viscosity performance in production tests need to be run daily. The new byko-visc RT provides you all the flexibility needed for any measurement task.
4 - 6000000 cP
4
0.2%
1.0% full scale range
0.0673 mNm
General
English German French Italian Spanish Russian Japanese Chinese
Worldwide power supply, 24v voltage DC input / Separate 24 VDC power supply
6.5 kg
14.3 lb
25 x 31 x 47 cm
9.8 x 12.2 x 18.5 in
Standards:
ISO
2555 1652
ASTM
D2196
Other Variations:
byko-visc RT R
2) 8358
byko-visc RT H
₹ 100000 / Piece Get Latest Price
| Model Name/Number | Ultrapyc 5000 Foam |
| Brand | anton paar |
| Material | Mild Steel |
| Usage/Application | Industrial |
| Type | Gas Pycnometer for Semi-Solid and Solid Density |
| Features | Get precise and hassle-free temperature control |
Anton Paar-Ultrapyc 5000 Foam
· Includes test methods and calculations of ASTM D6226 describing the open-cell content of foams
· PowderProtect: Measure samples without instrument contamination
· Built-in Peltier temperature control
· Accurate results for samples from 4.5 cm3 to 135 cm3
Technical specifications
|
|
Ultrapyc 3000 |
Ultrapyc 5000 |
Ultrapyc 5000 Foam |
Ultrapyc 5000 Micro |
|
Large cell (135 cm³) |
Accuracy: 0.02 % |
- |
||
|
Medium cell (50 cm³) |
Accuracy: 0.02 % |
- |
||
|
Small cell (10 cm³) |
Accuracy: 0.03 % |
- |
||
|
Micro cell (4.5 cm³) |
- |
Accuracy: 0.10 % |
||
|
Meso cell (1.8 cm³) |
- |
Accuracy: 0.30 % |
||
|
Nano cell (0.25 cm³) |
- |
Accuracy: 1.00 % |
||
|
Preparation mode(s) |
Flow or pulse |
Flow, pulse, or vacuum |
||
|
TruPyc technology |
Yes |
|||
|
TruLock lid |
Yes |
|||
|
PowderProtect mode |
No |
Yes |
||
|
Buit-in temperature control |
No |
15 °C to 50 °C |
||
|
Built-in foam methods and calculations |
No |
No |
Yes |
No |
|
Graphical user interface |
Yes |
|||
|
Transducer accuracy |
Better than 0.1 % |
|||
|
Pressure reading resolution |
Digital pressure readout 0.0001 psi |
|||
|
Connections |
4 USB ports |
|||
|
Instrument weight |
10 kg |
|||
|
Dimensions (W x D x H) |
27 cm x 48 cm x 25 cm |
|||
₹ 89000 / Piece Get Latest Price
| Usage/Application | Industrial |
| Model Name/Number | FRS 1800 |
| Brand | Anton Paar |
| Type | High Temperature Viscometer and Rheometer |
| Size/Dimension | 680 x 1950 x 920 mm |
| Weight | 150 kg |
Minimum order quantity: 1 Piece
|
technical specification |
Unit |
FRS 1800 |
|
Bearing |
- |
Air |
|
EC motor (brushless DC) with high resolution optical encoder |
- |
✔ |
|
Permanent torque (60 min), no signal drift |
- |
✔ |
|
EC mode (controlled shear rate and shear stress) |
- |
✔ |
|
Rotation mode |
- |
✔ |
|
Oscillation mode |
- |
✔ |
|
Measuring of newtonian samples |
- |
✔ |
|
Measuring of non-newtonian samples |
- |
✔ |
|
Maximum torque |
mNm |
230 |
|
Minimum torque, rotation |
nNm |
10 |
|
Minimum torque, oscillation |
nNm |
2 |
|
Torque resolution |
nNm |
0.1 |
|
Viscosity range |
Pa.s |
0.001–107 |
|
Angular deflection, set value |
µrad |
0.1 to ∞ |
|
Angular deflection, resolution |
nrad |
10 |
|
Minimum angular velocity |
rad/s |
10-9 |
|
Maximum angular velocity |
rad/s |
314 |
|
Minimum speed (CSS/CSR) |
1/min |
10-9 |
|
Maximum speed FRS |
1/min |
300 |
₹ 40000 / Piece Get Latest Price
| Wavelength Range | 400 - 700 nm |
| image Resolution | 821 x 821 |
| Power Consumption | 150VA |
| Sphere Diameter | Diameter 152 mm / 6.0 inches, Barium coated |
| Software Connection | Tools SV |
| Data Interface | Ethernet |
| Reporting interval | 10 nm |
| Weight-SpectraVision Vertical | 146 lbs. (66.22 kgs) |
| Lens | 50 mm, fixed focus |
| Weight-SpectraVision | 70 lbs (31.75kg) |
Minimum order quantity: 1 Piece
|
Features |
SpectraVision |
SpectraVision Vertical |
|
Instrument Type |
Barium coated sphere with xenon flash lamp, Diffuse illumination, 8º viewing in conformance with CIE publication No. 15.2 Colorimetry |
Barium coated sphere with xenon flash lamp, Diffuse illumination, 8º viewing in conformance with CIE publication No. 15.2 Colorimetry |
|
Light Source |
Pulsed xenon, filtered to provide D65 illumination including UV component. |
Pulsed xenon, filtered to provide D65 illumination including UV component. |
|
Sphere Diameter |
Diameter 152 mm / 6.0 inches, Barium coated |
Diameter 152 mm / 6.0 inches, Barium coated |
|
Wavelength Range |
400 – 700 nm |
400 – 700 nm |
|
Reporting interval |
10 nm |
10 nm |
|
Photometric range |
0 to 200% |
0 to 200% |
|
Spectral Analyzer |
Hyperspectral imaging assembly with 31 narrow bands covering 400 to 700 nm. The imaging is with a scientific 90 db camera with a sCMOS sensor. |
Hyperspectral imaging assembly with 31 narrow bands covering 400 to 700 nm. The imaging is with a scientific 90 db camera with a sCMOS sensor. |
|
|
Ports
2 Ethernet ports with 1 GBPS (Gigabit Network)
USB Port (2.0 Min)
|
Component |
Minimum Requirements |
|
Processor |
Intel i7 or Intel Xeon |
|
Memory RAM |
64 GB |
|
Hard Drive |
SSD 1 TB Min, 4 TB (4TB only needed if not using external storage.) |
|
Video Resolution |
1920×1080 – size of text only 100% supported |
|
DVD Drive |
DVD Writer |
|
Operating System |
Windows 10 & 11 Pro or Enterprise |
|
Authenticated Sybase Database, supplied with the system |
Sybase 12.0.1 EBF3994 Rev 4. |
|
Optional Textile Database upon request |
Microsoft SQL Server 2008, 2012 R2 |
|
Server OS |
Microsoft SQL Server 2016 |
₹ 650720 / Piece Get Latest Price
| Model Name/Number | HAAKE Viscotester 3 Rotational Viscometer |
| Brand | Thermofisher scientific |
| Power Supply | Operable by battery or power supply |
| Description | HAAKE Viscotester 3 Rotational Viscometer for higher viscosity measurements |
| Rotational Speed Range | 62.5 rpm |
| Temperature Range | Up to 150 DegreeC |
| Viscosity Range | 30 to 400 000 mPas |
Minimum order quantity: 1 Piece
Perform viscosity measurements with ease. The Thermo Scientific™ HAAKE™ Viscotester™ 3 rotational viscometer ensures quick, reliable tests for QC applications.
Use it as a handheld viscometer or on a lab stand. Color coding ensures measuring geometries match the analysis, the display is readable in any lighting, and the viscometer remembers the reference point measurement for you. All that comes in a ready-to-go carrying case.
Product Overview:
Designed for simplicity – The HAAKE Viscotester 3 Rotational Viscometer is built for ease of use to get you quickly to the right viscosity measurements:
· Smart alignment given by design and visualized by an electronic level
· Quick coupling of measuring geometries for fast and easy adaptation
· Color coded geometries and a geometry range indicator ensure correct rotor selection every time
· Adaptable display brightness ensures ideal readability in any environment
· Battery and power supply options allow the viscometer to be run anywhere
· Memory assist functionality allows you to quickly and easily compare measured viscosities with the reference point
· Selectable viscosity units (mPa s or dPa s)
· Compatibility with previous viscometer models
Recommended for: your entire process, from accepting the delivery of goods, to sampling during production and quality control (QC).
· Printing inks, paints, inks and other coatings
· Shampoos, creams, lotions, and similar personal care products
· Oil, greases, pastes and similar substances
· Sauces, thickeners, and similar food products
Specifications:
Description HAAKE Viscotester 3 Rotational Viscometer for higher viscosity measurements
Includes Base viscometer comes in carrying case with instrument holder (for lab stand), one measuring cup (No. 3), three rotors (No. 1, 2 and 3), four rechargeable batteries and one power supply adapter. Easily upgrade your Thermo Scientific HAAKE Viscotester 2 Plus viscometer to this model; the results are compatible.
Measuring Accuracy ± 5% FSD (rotors R1, R2, R3)
± 7.5% FSD (rotor R5)
± 10% FSD (rotor R4)
Power Supply Operable by battery or power supply
Rotational Speed Range 62.5 rpm
Temperature Range (Metric) Up to 150°C
Viscosity Range 30 to 400 000 mPas
Unit Size Each
₹ 80000 / Piece Get Latest Price
| Brand | Thermofisher scientific |
| Type | RheoScope Module |
| Camera | Black-and-white 'progressive' scan CCD camera, with 1024 x 768 pixels, C connector and IEEE 1394 |
| Data Storage | Up to 30 images per second in HAAKE RheoWin 4 software |
| Lens | 5X, 10X, 20X and 50X |
| Light Source | 150 W, 12 V, Wavelength Range: 380 to 750 nm |
Minimum order quantity: 1 Piece
₹ 430000 / Piece Get Latest Price
| Model Name/Number | CH-1912 |
| Brand | TOYOSEIKI |
| Material | Stainless Steel |
| Usage/Application | Industrial |
| Power | 3 kW |
| Frequency | 50Hz |
| Surface Finish | Color Coated |
| Warranty | Upto 1 Year |
Minimum order quantity: 1 Piece
Product Details:
| Usage/Application | Industrial |
| Brand | Toyoseiki |
| Warranty | Upto 1 Year |
| Voltage | 240 V |
| Power | 3 kW |
| Body Material | Stainless Steel |
| Surface Finish | Color Coated |
| Frequency | 50Hz |
₹ 70000 / Piece Get Latest Price
| Usage/Application | Industrial |
| Model Name/Number | MCR 702e MultiDrive |
| Brand | anton paar |
| Type | Modular Compact Rheometer |
| Size/Dimension | 444 x 753 x 586 mm |
| Weight | 48 kg |
Minimum order quantity: 1 Piece
Technical specifications
|
|
|
MCR 702e MultiDrive |
|
|
Technical Data |
Unit |
Configuration with 1 EC motor |
Configuration with 2 EC motors |
|
Bearing design |
- |
Air, fine-pored carbon |
|
|
Motor design |
- |
Electronically Commutated (EC) - Permanent Magnet Synchronous Motor |
|
|
Displacement transducer design |
- |
High-resolution optical encoder |
|
|
Normal force measurement design |
- |
360 ° capacitive sensor, non-contacting, fully integrated in bearing |
|
|
Active thermal management of bearing and normal force sensor |
- |
Yes |
Yes |
|
Working modes |
- |
Combined Motor Transducer (CMT) |
Separate Motor Transducer (SMT), |
|
Minimum torque (rotation) |
nNm |
1 |
1 |
|
Minimum torque (oscillation) |
nNm |
0.5 |
0.5 |
|
Maximum torque |
mNm |
230 |
230 |
|
Minimum angular deflection (set value) |
µrad |
0.05 |
0.05 |
|
Maximum angular deflection (set value) |
µrad |
∞ |
∞ |
|
Minimum angular velocity [2] |
rad/s |
0 |
0 |
|
Maximum angular velocity |
rad/s |
314 |
628 |
|
Minimum angular frequency [3] |
rad/s |
10 -7 |
10 -7 |
|
Maximum angular frequency [4] |
rad/s |
628 |
628 |
₹ 70000 / Piece Get Latest Price
| Usage/Application | Industrial |
| Model Name/Number | MCR 702e Space MultiDrive |
| Brand | Anton Paar |
| Type | Modular Compact Rheometer |
| Size/Dimension | 444 x 753 x 586 mm |
| Weight | 58 kg |
Minimum order quantity: 1 Piece
Technical specifications
|
|
|
MCR 702e MultiDrive |
|
|
Technical Data |
Unit |
Configuration with 1 EC motor |
Configuration with 2 EC motors |
|
Bearing design |
- |
Air, fine-pored carbon |
|
|
Motor design |
- |
Electronically Commutated (EC) - Permanent Magnet Synchronous Motor |
|
|
Displacement transducer design |
- |
High-resolution optical encoder |
|
|
Normal force measurement design |
- |
360 ° capacitive sensor, non-contacting, fully integrated in bearing |
|
|
Active thermal management of bearing and normal force sensor |
- |
Yes |
Yes |
|
Working modes |
- |
Combined Motor Transducer (CMT) |
Separate Motor Transducer (SMT), |
|
Minimum torque (rotation) |
nNm |
1 |
1 |
|
Minimum torque (oscillation) |
nNm |
0.5 |
0.5 |
|
Maximum torque |
mNm |
230 |
230 |
|
Minimum angular deflection (set value) |
µrad |
0.05 |
0.05 |
|
Maximum angular deflection (set value) |
µrad |
∞ |
∞ |
|
Minimum angular velocity [2] |
rad/s |
0 |
0 |
₹ 67000 / Piece Get Latest Price
| Usage/Application | Industrial |
| Model Name/Number | RheolabQC |
| Brand | anton paar |
| Type | Rotational Rheometer |
| Features | From single-point to more complex rheological analyses from liquids to semi-solids |
| speed | 0.01 1/min to 1200 1/min |
Minimum order quantity: 1 Piece
Anton Paar- RheolabQC
· Cost-effective modular rotational rheometer for routine tasks
· From single-point to more complex rheological analyses from liquids to semi-solids
· Controlled shear rate and shear stress, yield and thixotropic tests
· Worry-free use with automatic spindle recognition (Toolmaster™)
Key features
Technical specifications
|
Property |
Range |
|
Speed |
0.01 1/min to 1200 1/min |
|
Torque |
0.20 mNm to 75 mNm |
|
Shear stress |
0.5 Pa to 3 x 104 Pa |
|
Shear rate |
10-2 1/s to 6500 1/s |
|
Viscosity range |
1 mPa.s to 109 mPa.s |
|
Temperature range |
-20 °C to +180 °C |
|
Angular resolution |
2 µrad |
|
Physical variables (measurement or evaluation) |
|
₹ 1000 / Pack Get Latest Price
| Dimensions | 580 x 580 mm |
| Grade | 390 |
| Specifications | Narrow-pore, dense, slow filtering |
| Filter Material | 100 % Cotton Linters |
| Application Area | Analytical Sample Preparation Particle Analysis |
| Basis Weight | 84 |
Minimum order quantity: 1 Pack
Ash-free Filter Papers for Quantitative and Gravimetric Analysis
Sartorius offers a full portfolio of quantitative filter papers, used for quantitative and gravimetric analyses as well as pressure or vacuum filtration.
These 580 x 580 mm fast filtering, black dot filter paper sheets are used for quantitative and gravimetric analyses as well as for pressure or vacuum filtration.
· Application
Clarification
· Application Area
· Analytical Sample Preparation
· Particle Analysis
Dimensions· Dimensions
580 × 580 mm
· Filter Diameter
N/A
General Specifications· Filter Format
Sheets
· Filter Paper/Membrane Color
White
· Filtration Time
100 s
· Grade
390
· Specifications
Narrow-pore, dense, slow filtering
· Thickness
0.16 mm
Materials of Construction· Filter Material
100 % Cotton Linters (> 98 % alpha-cellulose; ash-free)
· Membrane Material
N/A
Physicochemical Information· Pore Size
N/A
· Precipitations
Fine crystalline
· Retention Rate
3–5 µm
Product Information· Filter Type
Quantitative Filter Papers
· Pack Size
100
· Packaging
Non-sterile, bulk packed
Weights· Basis Weight
84 g/m²
₹ 1000 / Pack Get Latest Price
| Filter Paper | White |
| Grade | FN 100 |
| Thickness | 0.35 mm |
| Filter Material | Cotton Linters |
| Packaging | Non-sterile, bulk packed |
| Basis Weight | 195g |
Minimum order quantity: 1 Pack
Filter Papers for the Absorption of Liquids
Whenever a liquid must be captured, Sartorius offers a large variety of paper grades to ensure best results. Filter Papers for Absorption are used not only for general absorption applications but also for blotting, chromatography, seed germination tests or even protection of surfaces.
Labsorb is a surface protection paper. It is a highly absorptive grade of paper coated on one side with polyethylene.
Applications· Application Area
Analytical Sample Preparation
Dimensions· Dimensions
460 mm × 50 m
· Filter Diameter
N/A
General Specifications· Filter Format
Reels
· Filter Paper/Membrane Color
White
· Grade
LabSorb
· Specifications
Polyethylene coated paper, absorption : 150 %
Materials of Construction· Filter Material
Polyethylene Coated Cellulose
· Membrane Material
N/A
Physicochemical Information· Pore Size
N/A
· Retention Rate
N/A
Product Information· Filter Type
Surface Protection Papers
· Pack Size
1
· Packaging
Non-sterile, bulk packed
Weights· Basis Weight
140 g/m²
Blotting & Chromatography PapersThis highly pure paper grade is not only ideal for blotting and chromatography, but also for a wide range of absorption applications like those common in the life sciences and diagnostics.
Applications
Blotting
Dimensions· Dimensions
100 × 100 m
· Filter Diameter
N/A
General Specifications· Capillary Rise / 10 Minutes
70 mm
· Capillary Rise / 30 Minutes
115 mm
· Filter Format
Reels
· Filter Paper/Membrane Color
White
₹ 44000 / Piece Get Latest Price
| I Deal In | New Only |
| Maximum Temprature Capacity | -20 DegreeC to +120 DegreeC |
| Country of Origin | Made in India |
| MATERIAL | Borosilicate 3.3 |
| WEIGHT | 13.5KG |
|
Discs: |
clear |
|
Use: |
Normal pressure |
|
Material: |
Borosilicate 3.3 |
|
Was standing: |
Rubber feet |
|
Temperature resistance: |
-20°C to +120°C |
CE
Technical information· Drying performance
· Open and close the door
Suppliers and importers of SICCO-DE are Chennai,Chegalpattu,kallakurichi,kanchipuram,mayiladurai,kanyakumari,Coimbatore,Namakkal,Ranipet,Tenkasi,thootukudi
|
External dimensions [W x H x D in mm] |
Usable interior space [W x H x D in mm] |
Internal volume [liters] |
Weight [kg approx.] |
Max. floor load with flat load [kg] |
Total load with flat load [kg] |
Supernatant dry unit [in mm] |
Article no. |
|
|
|
310x525x375 |
260x480x330 |
51 |
13.5 |
10 |
30 |
70 rear / back side |
V1823-07 |
|
Description
Product information "Auto-Star desiccator Vitrum | SICCO"
Product descriptionAluminum frame with panes made of heat-resistant borosilicate glass 3.3, rear wall made of aluminum, including four intermediate shelves made of stainless steel, hygrometer and mounted drying unit, can be equipped with up to 26 shelves, stackable. A 230 V / 50-60 Hz power connection is required.
Product advantages» reinforced aluminum frame with panes made of borosilicate glass 3.3
» door with magnetic strip and all-round rubber seal
» non-slip rubber feet
» easy-to-read electronic hygrometer
» variably adjustable intermediate shelves made of stainless steel
» automatic drying (no manual regeneration necessary)
» constantly low humidity in the interior between 20 and 30%
» Intermediate shelves can be pulled out
Direct storage for long-term storage of hot, oven-dried materials (max. 120 °C). When storing aggressive products, compatibility must be checked.
Thanks to automatic drying, the SICCO automatic desiccators with a constant humidity between 20 and 30% are very suitable for long-term storage. Even frequent opening of the door is automatically compensated for. An ideal storage solution for reference samples, electronic components, photographic equipment, papers, valuable cultural assets and much more.
₹ 61000 / Piece Get Latest Price
| Brand | Elcometer |
| Model Name/Number | 319 Dewpoint meter |
| Features | Large easy to read measurements in degrees DegreeC or DegreeF |
| application | Coating Inspection and To check weather/climate condition before painting |
| color | orange |
Minimum order quantity: 1 Piece
Elcometer 319 Dewpoint meter:
The Elcometer 319 Dewpoint Meter has been designed to measure and record all the relevant climatic parameters required to determine whether conditions are suitable for painting.
The Elcometer 319 Dewpont Meter with temperature sensor is fully designed to measure and record all relevant climate parameters that able to determine correct weather condition for suitable for painting.
Measure and record climatic parameters:
Visual and audible indication of user defined limits for any or all parameters | USB and Bluetooth® data output to ElcoMaster® software
Application:
₹ 10000 / Piece Get Latest Price
| Model Name/Number | SmartRef |
| Brand | anton paar |
| Packaging Type | carton box |
| Dimension | 108 mm x 64 mm x 35 mm |
| Weight | 135 g |
| Storage Temperature | 10 DegreeC - 40 DegreeC |
| features | Quick readings: results in under two seconds |
| Sample area material | Stainless steel and glass, FKM O-Ring |
| Battery lifetime | ~10,000 measurements |
Technical specifications
|
Measuring range |
|
|
Refractive index (RI) at 20°C |
1.3330 – 1.5040 |
|
Brix |
0° to 85° |
|
Sample temperature |
10 °C – 100 °C (50 °F – 212 °F) |
|
PSU (practical salinity units) |
0 – 50 |
|
Salinity ppt (parts per thousand) |
0 – 150 |
|
Salinity S.G. (20/20) |
1.000 – 1.114 |
|
Accuracy |
|
|
Refractive index (RI) |
±0.0003 |
|
Brix |
±0.2° |
|
Temperature |
0.5 °C (0.9 °F) |
|
PSU (practical salinity units) |
±2 |
|
Salinity ppt (parts per thousand) |
±2 |
|
Salinity S.G. (20/20) |
±0.002 |
|
Resolution |
|
|
Refractive index (RI) |
0.0001 |
|
Brix |
0.1° |
|
Temperature |
0.1 °C (0.1 °F) |
|
PSU (practical salinity units) |
1 |
|
Salinity ppt (parts per thousand) |
1 |
|
Salinity S.G. (20/20) |
0.001 |
|
Further specifications |
|
|
Sample volume |
0.4 mL |
|
Measurement time |
<2 s |
|
Automatic temperature compensation 20 °C (ATC) %Brix |
10 °C – 100 °C (50 °F – 212 °F) |
|
Automatic temperature compensation 20 °C (ATC) PSU, ppt, S.G. (20/20) |
10 °C – 40 °C (50 °F – 104 °F) |
|
Mobile operating system |
Android and iOS |
|
Data |
|
|
Dimensions (L x W x H) |
108 mm x 64 mm x 35 mm (4.3 in x 2.5 in 1.4 in) |
|
Weight (incl. batteries) |
~135 g (0.31 lbs) |
|
Power supply |
2x AAA 1.5V LR03 alkaline batteries (included) or AAA NiMH rechargeable batteries |
|
Enclosure rating |
IP66 according to IEC 60529 |
₹ 100000 / Piece Get Latest Price
| Usage/Application | Laboratory |
| Model Name/Number | Soft Drink Analyzer M |
| Dimension | 495 mm x 330 mm x 230 mm |
| brand | anton paar |
| Air humidity | 10 % to 90 % relative humidity, non-condensing |
| Ambient temperature | 15 DegreeC to 35 DegreeC (59 DegreeF to 95 DegreeF) |
| Interfaces | 4 x USB, RS-232, CAN, VGA, Ethernet |
| type | Sugar Inversion Analyzing System: |
Technical specifications
|
|
|
|
PBA-SID |
|
Patents granted |
AT 516420 (B1), AT 517082 (B1), AT 517486 (B1) |
||
|
Measuring range |
|||
|
Density |
0 g/cm³ to 3 g/cm³ |
||
|
Sound velocity |
1000 m/s to 2000 m/s |
||
|
Measuring temperature |
20 °C (68 °F)[1] |
||
|
Current/fresh/inverted sugar concentration |
0 °Brix to 80 °Brix |
0 °Brix to 15 °Brix |
|
|
Degree of inversion |
0 % to 100 % |
||
|
CO2 |
- |
- |
0 vol. to 6 vol. (0 g/L to 12 g/L) at 30 °C (86 °F) |
|
O2 |
|
|
0 ppm to 4 ppm |
|
%Diet concentration |
- |
0–200 % Diet or |
|
|
pH |
- |
pH 0 to pH 14 |
|
|
Accuracy[2] |
|||
|
Density |
0.000007 g/cm³ |
||
|
Temperature |
0.01 °C (0.02 °F) |
||
|
Repeatability s.d.[3] |
|||
|
Density |
0.000001 g/cm³ |
||
|
|
|||
₹ 10000 / Piece Get Latest Price
| Model Name/Number | AM 4201 |
| Usage/Application | Automobile Industry |
| Color | BLACK |
| Air Velocity | 0TO50 |
| Barometer | 45 |
Lutron YK 2005AM ANEMOMETER, Real time data logger + air flow
ANEMOMETER, Real time data logger + air flow
Model : YK-2005AM
* Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h,* Air flow : CMM ( m^3/min. ) and CFM ( ft^3/min. ).
* Air temperature ( , )
* Type K/ Type J thermocouple thermometer
* Real time data logger, build in clock ( hour-min.-sec., year-month-date ).
* Auto data record, 16,000 Data logger no. * High capacity, 16,000 data logger point.
* Wide sampling time adjustment range from two seconds to 8 hours 59 minutes 59 seconds
* RS232 computer interface.
* Can default auto power off or manual power off.
* Can default the air velocity, air flow, Temp. unit.
* Air flow measurement can set the area dimension.
* Multi function with easy operation
* Low-friction ball vane wheels make sure high accuracy in high & low velocities.
* Real time data logger (record year, month, date, hour, minute, second).
* Air velocity, Air flow, Temp., type K Temp.
* Metal vane, heavy duty.
* 0.4 to 30.0 m/s. CMM, CFM.
* Max., Min., Data hold.
* RS-232 computer interface.
* Optional data transmission software, SW-DL2005.
* Jumbo LCD display.
* DC 1.5V (UM3, AA) x 4 PCs or DC 9V adapter in.
* Size : 203 x 76 x 38 mm.
* Price Rs 1000
What are the different types of thermometers used to measure temperature?
The most familiar use of such thermometers is in ear thermometers that measureinfrared radiation from the tympanic membrane (ear drum) to determine body temperature. Other types of infrared thermometers include bolometers and pyrometers.
Being an Largest Importers of Lutron Products in India since 2005. Lutron products are mostly & widely used for everyday in various Pharmaceutical laboratories, Food Laboratories, Universities and for Research applications. Over a long period of time DFT Tech have been established as reliable Suppliers ,Importers and Stockists of Lutron All Range of Products in India, catering to the huge industry markets in Chennai, Bangalore, Coimbatore, Tiruchy, Madurai, Pune, Hyderabad, Ahemdabad, Calcutta, Mumbai and etc...
Apart from that we are supplying our Lutron products in India through dealers network, catering to a variety of customers ranging from Atomic energy, Biotechnology Companies, Microbiology Laboratory, Pharmaceutical Manufacturers, Defence Installations, Research Laboratories, Educational Institutes and various Research and Development laboratories of leading national and multinational companies.
We DFT Tech Lutron YK 2005AM ANEMOMETER, Real time data logger + air flow Authorized Distributors, Importers, Stockists, Dealers and Suppliers of Lutron YK 2005AM Anemometer Taiwan Make Products in Chennai, Bangalore, and etc..
₹ 75070 / Piece Get Latest Price
| Display | Graphic |
| Resolution | +-0.005 A |
| Accuracy | 2% Full scale |
| Light Source | 6 x LED |
| Product Line | AQUAfast |
| Backlight Option | yes |
| Languages | English, French, German, Spanish, Italian |
| Type | Colorimeter |
| Battery Type | AA |
Minimum order quantity: 1 Piece
Product Overview:
Features:
· Wide range of disinfectants in various formats to broaden our offering to a variety of industries
· Large graphic display with step-by-step user instructions
· Automatic countdown to measurement
· Consistent results from shift to shift
· Selectable languages of English, French, German, Italian, Spanish, Portuguese (Brazilian), and Polish with other languages uploadable via RJ 45 connection
Requires:
· 4 AA batteries
Recommended for:
· Wastewater
· Drinking water
· Nutrient monitoring
· Environmental testing
· Food and beverage
· Industrial applications
Specifications:
Accuracy 2% Full scale
Backlight Option Yes
Certifications/Compliance FCC Part 15; CE
Cuvette Details Round 13 mm, 16 mm, 24 mm & 16 mm COD Digestion Tubes
Battery Type AA
Display Graphic
Languages English, French, German, Spanish, Italian
Light Source 6 x LED
Product Line AQUAfast
Type Colorimeter
Wavelength Range 430, 530, 560, 580, 610, 660 nm
Interface Internal RJ45 port
Keypad Numeric keys, ON/OFF, Up, Down, Enter, Timer, Zero, Test, Cal, Mode, Store, Shift, plus 3 Function keys
Outputs IRDA
Reagent Form Powder, tablet, liquid, reagent tubes, digestion tubes. Color, Turbidity and Suspended Solids tests do not require reagents
Resolution ±0.005 A
Sample Size 10 mL
Storage Requirements 5°C to 40°C
Test Method Up to 90 and 10 user defined programmed methods
Unit Size Each
Get Latest Price
| Model Name/Number | Brabender MetaStation 4 |
| Brand | Anton Paar |
| Type | Modular Torque Rheometer |
| Size/Dimension | 700 mm x 870 mm x 950 mm |
| Weight | 154 kg |
Anton Paar- Brabender MetaStation 4
· Drive for small mixers, single- and twin-screw extruders
· Application as table-top device possible due to compact design
· Speed control: 0.2 min-1 to 185 min-1 with 200 Nm max. torque
· Smart drive and control unit to gain deep process knowledge
· MetaBridge for analyzing time-dependent process variables
The market-leading Brabender MetaStation is a versatile, modular drive unit and torque rheometer for determining the processability and material characteristics of different plastics and plastifiable substances, compliant with key ASTM standard methods. Tailor it to your specific PVC, rubber, or thermoset testing needs, using our portfolio for varied blade geometries, mixer sizes, and temperature control. In addition to batch-wise compounding and mixing, continuous processes are also possible via the use of single- and double-screw extrusion attachments of different scales. MetaStation: Today's configuration flexibility, tomorrow's infinite possibilities.
Key features
Technical specifications
|
|
MetaStation 4 |
|
Drive output |
4.2 kW |
|
Torque and speed |
200 Nm, 0.2 min-1 to 185 min-1 |
|
Speed deviation |
0.2 % through digital feedback |
|
Integrated temperature control |
6 zones |
|
Connectivity |
- MetaBridge Connect |
|
Safety devices |
- Emergency motor stop button |
|
Power supply: |
3 × 400 V 50/60 Hz + N + PE, 32 A |
|
Dimensions (W x H x D) |
700 mm x 870 mm x 950 mm |
|
Weight (net) |
154 kg |
Get Latest Price
| Model Name/Number | Brabender MetaStation 8 |
| Brand | Anton Paar |
| Type | Modular Torque Rheometer |
| Features | From PVC to thermosets: MetaStation's versatile mixer attachments |
| Size/Dimension | 700 mm x 870 mm x 950 mm |
| Weight | 154 kg |
Anton Paar- Brabender MetaStation 8
· Drive for mixers and for medium sized lab-scale extruders
· Ready for higher torque requirements compared to MetaStation 4
· Speed control: 0.2 min-1 to 200 min-1 with 400 Nm max. torque
· Smart drive and control unit to gain deep process knowledge
· MetaBridge for analyzing time-dependent process variables
The market-leading Brabender MetaStation is a versatile, modular drive unit and torque rheometer for determining the processability and material characteristics of different plastics and plastifiable substances, compliant with key ASTM standard methods. Tailor it to your specific PVC, rubber, or thermoset testing needs, using our portfolio for varied blade geometries, mixer sizes, and temperature control. In addition to batch-wise compounding and mixing, continuous processes are also possible via the use of single- and double-screw extrusion attachments of different scales. MetaStation: Today's configuration flexibility, tomorrow's infinite possibilities.
Key features
Technical specifications
|
|
MetaStation 8 |
|
Drive output |
8 kW |
|
Torque and speed |
400 Nm, 0.2 min-1 to 200 min-1 |
|
Speed deviation |
0.2 % through digital feedback |
|
Integrated temperature control |
6 zones |
|
Connectivity |
- MetaBridge Connect |
|
Safety devices |
- Emergency motor stop button |
|
Power supply: |
3 × 400 V 50/60 Hz + N + PE, 63A |
|
Dimensions (W x H x D) |
700 mm x 870 mm x 950 mm |
|
Weight (net) |
154 kg |
₹ 90000 / Piece Get Latest Price
| Capacity | 0.5 L |
| Ultrasonic Frequency | 30 kHz |
| Display Mode | Digital |
| Body Material | Plastic |
| Max. Temperature | upto 70 degC |
| Usage Area | Medical |
| Color | white |
| application | It will be specially used for cleaning pores & cold mounted irregular shape samples. |
| model name | Bransonic Ultrasonic Cleaners |
Minimum order quantity: 1 Piece
Bransonic Ultrasonic Cleaners:
General Description Bransonic M and MH Series cleaners are known for offering a level of precision and reliability you have come to expect from Branson. • M Series includes 60-minute mechanical timer and continuous operation. • MH Series includes 60-minute mechanical timer and continuous operation with heating capability. M and MH Series cleaners offer the following features: • Sweep frequency eliminates standing waves and creates consistent cavitation throughout the tank. • 40 kHz rugged industrial transducers. • Controls are located above and behind the cleaning tank in an easily accessible control tower panel, and raised above the tank to avoid damage from cleaning solutions. • Convenient built-in pour drains are featured on .5- and .75-gallon models. Tank drains with valves are incorporated on models 1.5-gallon and larger. • Plastic body, chemical-resistant. • Constant activity/power tracking automatically maintains the ultrasonic power by adjusting for changes in liquid level and temperature caused by a light or heavy load. This helps ensure more uniform cleaning and consistent performance, even with multiple users or when bath conditions change. NOTE: Tank cover included. For optimum cleaning results, Branson offers a line of accessories including perforated trays, solid trays, beaker covers and support racks for your application needs.
Application:
It will be specially used for cleaning pores & cold mounted irregular shape samples.
₹ 5000 / Piece Get Latest Price
| Equipment Type | Electric Gun |
| Adhesive Type | Cyanoacrylate |
| Operation Mode | Automatic |
| Mounting | Hand Held |
| Control Type | Timer |
| Applications | Electronics |
| Power Supply | 230 V AC |
| Number of Components | Three Component |
| Country of Origin | India |
GLUE DISPENSER
ELECTROMAX TECHNOLOGY
We are importers,stockists,and suppliers of
ELECTROMAX TECHNOLOGY India- Chennai Coimbatore ,Madurai, Kerala, Assam, Nagaland, Mizoram, Manipur, Trichy, Hosur, Tumkur, MYSORE, KOLKATA,SALEM ,POONAMALLEE, ,and more.
We at DFT TECH are proud to be Distributors of ELECTROMAX TECHNOLOGY
Product Description
DIGITAL Automatic Glue Dispensing Machine Precise Dispensing Controller Glue Machine With all Accessories₹ 30000 / Piece Get Latest Price
| Brand | Anton paar |
| Usage/Application | Laboratory |
| Model Name/Number | Compact digital density meter:DMA 1001 |
| Dimensions | 375 mm x 265 mm x 180 mm (14.8 in x 10.4 in x 7.0 in) |
| Material | Borosilicate glass, PTFE |
| Capacity | Approx. 1 mL |
| Type | digital density meter |
| Model Number | DMA 1001 |
| Power Supply | AC 100 to 240 V; 47 to 63 Hz; DC 24V, 3A |
| Use | Integrated temperature and humidity sensor for intelligent condition monitoring Built-in pressure |
| Color | white |
| Communication interfaces | 1 x Ethernet, 3 x USB, 1 x RS232 |
| Internal storage | 5000 measured results; 400 products |
Minimum order quantity: 1 Piece
Benefits:
· Upgrade your density measurements and leave your time-intensive, breakage-prone hydrometers behind. Over 60 integrated conversion tables, 400 freely configurable methods, and memory for up to 5000 data logs set the benchmark in this segment. Set up the device once with all your frequently used tests and return to them again and again to immediately see a clear “pass/fail” result based on your defined acceptable upper and lower limits. As DMA 501/1001 requires only 1 mL sample volume you won’t waste valuable product. Both instruments thrive in harsh environments and automatically compensate for external influences such as humidity, altitude, and ambient temperature. When linked to AP Connect, our lab execution software, all data is stored in a single digital space and accessible from any network computer.
Standard:
ABNTNBR 140651001
NBR 156391001
ASTMD12501001
D14751001
D25011001
D40521001
D48061001
D50021001
D59311001
D64481001
Chinese Pharmacopoeia (ChP)ChP 2020 (Vol IV) 0601501, 1001
DIN517571001
IP3651001
ISO2811-31001
121851001
15212-1501, 1001
183011001
JISK 00611001
K 22491001
Japanese Pharmacopoeia (JP)JP 17 2.561001
Technical specification
|
Patents |
EP3012612B1, AT520632B1, US10145771B2 |
|
Measuring range |
Density: 0 g/cm³ to 3 g/cm³ |
|
Temperature: 15 °C to 60 °C (59 °F to 140 °F) |
|
|
Repeatability, s.d.* |
Density: 0.00005 g/cm³ |
|
Reproducibility, s.d.* |
Density: 0.00007 g/cm³ |
|
Accuracy** |
Density: 0.0001 g/cm³ |
|
Digital Resolution |
Density: 0.00001 g/cm³ |
|
U-View™ |
Yes |
|
FillingCheck™ |
Yes |
|
Full-range viscosity correction |
Yes |
|
Minimum sample volume |
Approx. 1 mL |
|
Integrated tables and functions |
Density, Specific Gravity (SG), alcohol tables, sugar/extract tables, various acid/base tables, API functions |
|
Wetted parts |
Borosilicate glass, PTFE |
|
Dimensions (L x W x H) |
375 mm x 265 mm x 180 mm (14.8 in x 10.4 in x 7.0 in) |
|
Weight |
13.5 kg (29.8 lb) |
|
Power supply |
AC 100 to 240 V; 47 to 63 Hz; DC 24V, 3A |
|
Display |
7 inches, TFT WVGA (800 x 480 Px); PCAP touchscreen |
₹ 39000 / Piece Get Latest Price
| Brand | Anton paar |
| Usage/Application | Laboratory |
| Model Name/Number | DMA 5001 |
| Dimensions | 526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in) |
| Material | PTFE, borosilicate glass |
| Power Supply | AC 100 to 240 V, 50/60 Hz, fluctuation +-10 %, 190 VA |
| Use | QM compliance, temperature scan, built-in ambient pressure sensor, condition monitoring adjustment |
| Color | white |
| Optional accessories | Aerosol adapter, heating attachment |
| Minimum sample volume | Approx. 1 mL |
| Communication interfaces | 5 x USB, Ethernet, CAN, RS232 |
| Internal storage | More than 10,000 measuring values with camera images |
Minimum order quantity: 1 Piece
Standards
2020 Chinese Pharmacopoeia0601-relative density determination method4101, 4501, 5001
ABNTNBR 140654101, 4501, 5001
NBR 156394101, 4501, 5001
AOAC982.104101, 4501, 5001
ASBCBeer-2B: Specific Gravity by digital density meter (1978)4101, 4501, 5001
Beer-5: Real Extract (B. Beer measured gravimetrically (1958), C. Real Extract determined refractometrically (1982))4101, 4501, 5001
ASTMD12504101, 4501, 5001
D14754101, 4501, 5001
D25014101, 4501, 5001
D40524101, 4501, 5001
D48064501, 5001
D50024101, 4501, 5001
D59314101, 4501, 5001
D64484101, 4501, 5001
Technical specification
Density 0 g/cm³ to 3 g/cm³
Temperature 0 °C to 100 °C (32 °F to 212 °F)
Pressure Up to 10 bar (145 psi) absolute pressure
Density 0.000001 g/cm³
Power features U-View™, FillingCheck™, ThermoBalance™, full-range viscosity correction
Special functions QM compliance, temperature scan, built-in ambient pressure sensor, condition monitoring adjustment at high viscosity (only DMA 5001 )
Automation Automatic sample changers
Modularity pH, alcohol, CO2, O2, color, turbidity, refractive index
Optional accessories Aerosol adapter, heating attachment
Typical measuring time/sample 40 s
Minimum sample volume Approx. 1 mL
Wetted materials PTFE, borosilicate glass
Dimensions (L x W x H) 526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in)
Weight 22.04 kg (48.6 lbs)
Power supply AC 100 to 240 V, 50/60 Hz, fluctuation ±10 %, 190 VA
Display 10.1" TFT WXGA (1280 x 800 px); PCAP touchscreen
Controls Touchscreen, optional keyboard, mouse, and barcode reader
Communication interfaces 5 x USB, Ethernet, CAN, RS232
Internal storage More than 10,000 measuring values with camera images
₹ 36000 / Piece Get Latest Price
| Brand | Anton paar |
| Usage/Application | Laboratory |
| Model Name/Number | DMA 35 Standard |
| Dimensions | 245 mm x 103 mm x 126 mm |
| Capacity | 2 mL |
| Type | Portable density meter |
| Model Number | DMA 35 Standard |
| Power Supply | Three 1.5 V LR06 AA alkaline batteries |
| Use | Viscosity correction for reliable measurements, also on highly viscous samples Gesture control |
| Color | white |
| Weight | 660 g |
| Data memory | 1024 measured results, 30 measuring methods, 250 sample IDs |
Minimum order quantity: 1 Piece
Key features:
Quickly determining the state of charge of lead-acid batteriesStandards:
ASTMD7777
Energy InstituteIP 559
ISO15212-1
Technical specification
|
Patents granted |
Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1), CN 105571982 B |
|
Other special functions |
Viscosity correction for reliable measurements, also on highly viscous samples |
|
Measuring range |
Density: 0 g/cm³ to 3 g/cm³ |
|
Accuracy |
Density: 0.001 g/cm³ ** |
|
Repeatability, s.d.*** |
Density: 0.0005 g/cm³ ** |
|
Reproducibility, s.d.*** |
Density: 0.0007 g/cm³ |
|
Digital Resolution |
Density: 0.0001 g/cm³ |
|
Ambient temperature**** |
Standard Version, Ampere Version: -10 °C to +50 °C (14 °F to 122 °F) |
|
Supported measuring units |
|
|
Sample volume |
2 mL |
|
Dimensions (L x W x H) |
245 mm x 103 mm x 126 mm |
|
Data memory |
1024 measured results, 30 measuring methods, 250 sample IDs |
|
Power supply |
Three 1.5 V LR06 AA alkaline batteries |
|
Weight |
660 g |
|
Interfaces |
Bluetooth®, RFID (both included by default) |
|
Protection class |
IP54 |
|
Intrinsic safety of Ex and Ex Petrol version |
ATEX: II 2G Ex ib IIB T4 Gb |
₹ 31000 / Piece Get Latest Price
| Brand | Anton paar |
| Usage/Application | Laboratory |
| Model Name/Number | DMA 35 Ex |
| Dimensions | 245 mm x 103 mm x 126 mm |
| Capacity | 2 mL |
| Type | Portable density meter |
| Model Number | DMA 35 Ex |
| Power Supply | Three 1.5 V LR06 AA alkaline batteries |
| Use | Viscosity correction for reliable measurements, also on highly viscous samples Gesture control |
| Color | white |
| Weight | 660 g |
| Interfaces | Bluetooth, RFID |
Minimum order quantity: 1 Piece
Standards:
ASTMD7777
Energy InstituteIP 559
ISO15212-1
|
Patents granted |
Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1), CN 105571982 B |
|
Other special functions |
Viscosity correction for reliable measurements, also on highly viscous samples |
|
Measuring range |
Density: 0 g/cm³ to 3 g/cm³ |
|
Accuracy |
Density: 0.001 g/cm³ ** |
|
Repeatability, s.d.*** |
Density: 0.0005 g/cm³ ** |
|
Reproducibility, s.d.*** |
Density: 0.0007 g/cm³ |
|
Digital Resolution |
Density: 0.0001 g/cm³ |
|
Ambient temperature**** |
Standard Version, Ampere Version: -10 °C to +50 °C (14 °F to 122 °F) |
|
Supported measuring units |
|
|
Sample volume |
2 mL |
|
Dimensions (L x W x H) |
245 mm x 103 mm x 126 mm |
|
Data memory |
1024 measured results, 30 measuring methods, 250 sample IDs |
|
Power supply |
Three 1.5 V LR06 AA alkaline batteries |
|
Weight |
660 g |
|
Interfaces |
Bluetooth®, RFID (both included by default) |
|
Protection class |
IP54 |
|
|
₹ 35000 / Piece Get Latest Price
| Brand | Anton paar |
| Usage/Application | Laboratory |
| Model Name/Number | DMA 35 Ex Petrol |
| Dimensions | 245 mm x 103 mm x 126 mm |
| Capacity | 2 mL |
| Type | Portable density meter |
| Model Number | DMA 35 Ex Petrol |
| Power Supply | Three 1.5 V LR06 AA alkaline batteries |
| Use | Viscosity correction for reliable measurements, also on highly viscous samples Gesture control |
| Color | white |
| Weight | 660 g |
| Interfaces | Bluetooth, RFID |
Minimum order quantity: 1 Piece
Standards:
ASTMD7777
Energy InstituteIP 559
ISO15212-1
Technical specification
|
Patents granted |
Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1), CN 105571982 B |
|
Other special functions |
Viscosity correction for reliable measurements, also on highly viscous samples |
|
Measuring range |
Density: 0 g/cm³ to 3 g/cm³ |
|
Accuracy |
Density: 0.001 g/cm³ ** |
|
Repeatability, s.d.*** |
Density: 0.0005 g/cm³ ** |
|
Reproducibility, s.d.*** |
Density: 0.0007 g/cm³ |
|
Digital Resolution |
Density: 0.0001 g/cm³ |
|
Ambient temperature**** |
Standard Version, Ampere Version: -10 °C to +50 °C (14 °F to 122 °F) |
|
Supported measuring units |
|
|
Sample volume |
2 mL |
|
Dimensions (L x W x H) |
245 mm x 103 mm x 126 mm |
|
Data memory |
1024 measured results, 30 measuring methods, 250 sample IDs |
|
Power supply |
Three 1.5 V LR06 AA alkaline batteries |
|
Weight |
660 g |
|
Interfaces |
Bluetooth®, RFID (both included by default) |
|
Protection class |
IP54 |
|
Intrinsic safety of Ex and Ex Petrol version |
ATEX: II 2G Ex ib IIB T4 Gb |
₹ 40000 / Piece Get Latest Price
| Brand | Anton paar |
| Usage/Application | Laboratory |
| Model Name/Number | DMA 35 Basic |
| Dimensions | 140 mm x 138 mm x 27 mm (5.5 x 5.4 x 1.0 inches) |
| Capacity | 2 mL |
| Type | Handheld density meter |
| Model Number | DMA 35 Basic |
| Power Supply | Two 1.5 V LR06 AA alkaline batteries |
| Use | Ideal for the use in tight spaces or of difficult-to-reach samples |
| Color | white |
Minimum order quantity: 1 Piece
DMA 35 Basic
15212-1
Energy InstituteIP 559
ISO15212-1
JISK 0061
Technical specification
|
Measuring range |
Density: 0 g/cm³ to 3 g/cm³ |
|
Accuracy |
Density: 0.001 g/cm³ ** |
|
Repeatability, s.d.*** |
Density: 0.0005 g/cm³ |
|
Reproducibility, s.d.*** |
Density: 0.0007 g/cm³ |
|
Digital Resolution |
Density: 0.0015 g/cm³ |
|
Ambient temperature*** |
-10 °C to +50 °C (14 °F to 122 °F) |
|
Supported measuring units |
|
|
Sample volume |
2 mL |
|
Dimensions (L x W x H) |
140 mm x 138 mm x 27 mm (5.5 x 5.4 x 1.0 inches) |
|
Data memory |
1024 measured results, 20 measuring methods, 100 sample IDs |
|
Power supply |
Two 1.5 V LR06 AA alkaline batteries |
|
Weight |
345 g (12.2 ounces) |
|
Interfaces |
IrDA OBEX/LPT |
|
Protection class |
IP54 |
|
Intrinsically safe |
no |
|
Available options |
|
|
Industries |
|
|
|
* Filling at higher temperatures possible |
₹ 40000 / Piece Get Latest Price
| Brand | Anton paar |
| Usage/Application | Laboratory |
| Model Name/Number | DMA 4200 M |
| Dimensions | 510 mm x 330 mm (20 in x 13 in) |
| Material | Hastelloy C276 |
| Power Supply | AC 100 to 240 V, 50 to 60 Hz, 250 VA |
| Use | Quality control of petroleum samples |
| Color | white |
| ASTM standards | D4052, D5002 |
| Minimum sample volume | 2 mL |
| Pulsed Excitation Method | Yes |
Minimum order quantity: 1 Piece
NBR 14065
NBR 15639
ASTMD1475
D4052
D4806
D5002
D5931
D6448
D7961
D8188
GBT 2013-2010
T 11540-2008
T 13531.4-2013
ISO12185
RANP5
19
20
30
40
45
50
52
58
71
669
764
778
807
U.S. Pharmacopoeia (USP)USP 841 - Specific gravity
Technical specification:
|
Patent granted |
AT 516420 B1 |
|
Measuring range |
|
|
Pressure range |
0 bar to 500 bar (7250 psi) |
|
Accuracy* |
|
|
Repeatability, s.d.** |
|
|
Reproducibility, s.d.** |
|
|
Digital Resolution |
|
|
FillingCheck™ |
Yes (at ambient pressure and up to 150 °C) |
|
Full range viscosity correction |
Yes (at ambient pressure) |
|
Temperfect™ |
Yes (at ambient pressure) |
|
Pulsed Excitation Method |
Yes |
|
Minimum sample volume |
2 mL |
|
Wetted materials |
Hastelloy C276 |
|
Footprint |
510 mm x 330 mm (20 in x 13 in) |
|
ASTM standards |
D4052, D5002 |
|
Power supply |
AC 100 to 240 V, 50 to 60 Hz, 250 VA |
|
Connections |
Pressure fittings for metal tubes with 1/8" outer diameter |
|
Interfaces |
4 x USB (2.0 full speed), |
₹ 20000 / Piece Get Latest Price
| Measurement Range | 0 to 600 % reflectance |
| Weight | 3.5 kg |
| Measuring Area | 87 x 23 mm (3.4 x 0.9 in) |
| Measuring time | < 6 seconds |
| Memory | 1000 standards / samples |
| Power supply | External power supply 24 VDC |
| Operating temperature | 10 - 42 DegreeC |
| Dimensions: L x W x H | 21 x 12.5 x 17.5 cm |
Minimum order quantity: 1 Piece
Byk instruments-Automated color measurement ready for Industry 4.0
Features:
Technical Attributes:
Color Measurement
45° illumination; -15°, 15°, 25°, 45°, 75°, 110° aspecular viewing
87 x 23 mm (3.4 x 0.9 in)
400 - 700 nm, 10 nm resolution
0 to 600 % reflectance
0.01 ΔE* (10 consecutive measurements on white)
Grey BCRA II tiles: avg. ΔE* < 0.10 Chromatic BCRA II tiles: avg. ΔE* < 0.25
ΔE*; ΔE CMC; ΔE 94; ΔE 2000; ΔE 99; ΔE DIN6175 and customer specific scales
Flop, Int-Em
A; C; D50; D65; F2; F7; F11; F12; CIE 015:2018 LED illuminants
2°; 10°
Effect Measurement
15°, 45°, 75° and diffused illumination; perpendicular viewing with camera
ΔS; ΔS_a; ΔS_i; ΔG
S_a / S_i: 5% or > 0.50 / G = ± 0.05
S_a / S_i: 10% or > 1.00 / G = ± 0.15
Radius > 40 cm
Vibration-free operation
General
< 6 seconds
1000 standards / samples
RS 422
External power supply 24 VDC
3.5 kg
7.7 lb
10 - 42 °C
50 - 110 °F
up to 85%, 35° C (95° F); non-condensing
21 x 12.5 x 17.5 cm
8.3 x 5 x 6.9 in
Standards:
11664
D2244
E308
E1164
E2194
J1545
5033
5036
6174
6175-2
₹ 10000 / Piece Get Latest Price
| Viewing Area | 32 x 60 cm (sample table) |
| Light Source for Daylight | Fluorescent tube |
| Power supply | 115/230 V, 50/60 Hz |
| Weight | 58.8 kg |
| Dimensions: L x W x H | 76 x 80 x 121 cm |
Minimum order quantity: 1 Piece
Features:
Color evaluation of effect finishes with excellent agreement to BYK-mac i.
· Color evaluation under 6 defined viewing angles: -15° / 15° / 25° / 45° / 75° / 110°
· Excellent agreement with BYK-mac i as the 45° illumination pivots together with the sample table..
· Sparkle evaluation under 15°, 45° and 75° direct illumination: Three individual LED sets simulate direct sunlight – lamp life guaranteed for 10 years
· No warm-up or flickering which ensures quick and reliable judgements
· Timer to track daylight lamp usage and indicates when to replace the lamp
· Dimmable sparkle illumination to adjust for different sample lightness
Technical Attributes:
32 x 60 cm (sample table)
12.6 x 23.6 in (sample table)
Fluorescent tube
General
115/230 V, 50/60 Hz
58.8 kg
127.2 lb
76 x 80 x 121 cm
29.9 x 31.7 x 47.7 in
₹ 30000 / Piece Get Latest Price
| Brand | anton paar |
| Model Name/Number | MCP 150 |
| Usage/Application | Industrial |
| Weight | 8.6 kg |
| Dimension | 370 mm x 320 mm x 130 mm |
| Color | white |
| Resolution | 0.001 Degree |
Minimum order quantity: 1 Piece
Anton Paar- MCP 150:
· Modular Compact Polarimeter
Technical specifications
|
|
MCP 150 |
|
Measuring scales: |
°Optical Rotation, °Specific Rotation, %Concentration, user-defined scales |
|
Measuring range: |
±89.9° |
|
Resolution: |
0.001° |
|
Accuracy: |
±0.004° |
|
Repeatability: |
±0.004° |
|
Response time: |
max. 12 sec. |
|
Wavelength: |
589 nm |
|
Light source: |
LED, with average lifetime of 100 000 hours |
|
Sensitivity: |
Light intensity control compensates attenuation up to Optical Density (OD) 2.0 |
|
Temperature sensor: |
Built-in PT 100 sensor |
|
Temperature resolution: |
0.1 °C |
|
Temperature accuracy: |
±0.1 °C |
|
Temperature control: |
Automatic Peltier temperature control between 15 °C and 35 °C, or without temp. control |
|
Sample cell / quartz control plate: |
Toolmaster™ automatic sample cell and quartz control plate identification; sample cell path length of 2.5 mm to 100 mm |
|
Display: |
TFT touchscreen 5.7" (145 mm), 640 x 480 Pixels |
|
Interfaces: |
3 USB, RS232, Ethernet, CAN bus, 1 USB typ "B" for service Easy connection of keyboard, mouse, printer, bar code. Network capability. |
|
Dimensions (LxWxH): |
370 mm x 320 mm x 130 mm (14.6 in x 12.6 in x 5.1 in) |
|
Weight: |
8.6 kg (19 lbs) |
|
Power supply / consumption: |
AC 100 to 240 VAC, 50/60Hz / 70VA, 120 VA max. |
₹ 33000 / Piece Get Latest Price
| Brand | anton paar |
| Model Name/Number | MCP 100 |
| Display | TFT touchscreen 5.7" (145 mm), 640 x 480 Pixels |
| Weight | 7.8 kg |
| Dimension | 370 mm x 320 mm x 130 mm |
| Color | white |
Minimum order quantity: 1 Piece
Anton Paar- MCP 100
Technical specifications
|
|
MCP 100 |
|
|
Measuring scales: |
°Optical Rotation, °Specific Rotation, %Concentration |
|
|
Measuring range: |
±89.9° |
|
|
Resolution: |
0.001° |
|
|
Accuracy: |
±0.01° |
|
|
Repeatability: |
±0.01° |
|
|
Response time: |
12 sec. |
|
|
Wavelength: |
589 nm |
|
|
Light source: |
LED, with average lifetime of 100.000 hours |
|
|
Sensitivity: |
A light intensity control compensates attenuation up to Optical Density (OD) 2.0 |
|
|
Temperature sensor: |
Built-in PT 100 sensor |
|
|
Temperature resolution: |
0.1 °C |
|
|
Temperature accuracy: |
±0.2 °C |
|
|
Temperature control: |
Automatic Peltier temperature control at 20°C and 25°C, or without temp. control |
|
|
Sample cell / quartz control plate: |
Toolmaster™ - Automatic sample cell and quartz control plate identification; sample cell path length of 2.5 mm to 100 mm |
|
|
Display: |
TFT touchscreen 5.7" (145 mm), 640 x 480 Pixels |
|
|
Interfaces: |
3 USB, RS232, Ethernet, CAN bus, easy connection of keyboard, mouse, printer, bar code. Network capability |
|
|
Dimensions (LxWxH): |
370 mm x 320 mm x 130 mm (14.6 in x 12.6 in x 5.1 in) |
|
|
Weight: |
7.8 kg (17.2 lbs) |
|
|
Power supply / consumption: |
AC 100 to 240 VAC, 50/60Hz / 70VA, 120 VA max. |
₹ 34000 / Piece Get Latest Price
| Brand | anton paar |
| Model Name/Number | MCP 5100 |
| Light Source | LED |
| Measuring Range | +-89.9 DegreeOR |
| Color | white |
| Resolution | 0.0001 DegreeOR |
Minimum order quantity: 1 Piece
Technical specifications
|
|
||
|
Specifications MCP 5100 |
||
|
Measuring Scales |
°Optical Rotation, °Optical Rotation (cell-length corrected), °Specific Rotation,°Specific Rotation (cell-length corrected), % concentration (g/100 mL, g/L, g/100 cm³, kg/m³), °International Sugar Scale (not temperature-compensated), mathematic functions, and user-definable scales |
|
|
Measuring range |
±89.9 °OR |
|
|
Accuracy |
±0.002 °OR across entire range |
|
|
Repeatability |
±0.002 °OR |
|
|
Resolution |
0.0001 °OR |
|
|
Available wavelenghts |
589 nm standard |
|
|
Temp. control range |
Peltier temperature control |
|
|
Temp. accuracy |
±0.1 °C |
|
|
Temp. control speed |
2 °C sample temperature gradient eliminated in less than 30 seconds. |
|
|
21 CFR Part 11 compliance |
yes |
|
|
User Assistance Features |
||
|
FillingCheck™ camera |
no |
|
|
Automatic detection of sample cell and quartz standard by Toolmaster™ function |
yes |
|
|
Automated calibration / adjustment process by Toolmaster™ function |
yes |
|
₹ 100000 / Piece Get Latest Price
| Usage/Application | Industrial Use |
| Packaging Type | carton box |
| brand | anton paar |
| model name | PSA 1090 |
| weight | 55 kg |
| dimension | 890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in |
Anton Paar-PSA 1090
· Dual laser system
· Measurement range liquid: 0.04 µm to 500 µm
· Measurement range dry: 0.1 µm to 500 µm
·
Technical specifications:
|
|
PSA 1090 |
|
Measurement principle |
Laser diffraction |
|
Measuring range (dry) |
0.1 μm to 500 μm |
|
Measuring range (wet) |
0.4 μm to 500 μm |
|
Dry dispersion |
Venturi |
|
Liquid dispersion |
2 peristaltic pumps/ultrasonic transducer/stirrer |
|
Repeatability |
<1 % |
|
Accuracy |
<3 % |
|
Measuring time |
<1 min |
|
Number of lasers |
2 |
|
Laser safety classification |
FDA Title 21 CFR - Part 1040 & EN 60825-1:2014 |
|
Laser class, closed cover |
Class 1 of EN 60825-1:2014 |
|
Laser class, open cover |
Class 3R of EN 60825-1:2014 |
|
Digital data security |
FDA Title 21 CFR - Part 11 |
|
Electromagnetic compatibility |
EN 61326-1:2013 |
|
Low voltage |
EN 61010-1:2010 & EN 61010-2-081:2015 |
|
Dimensions (L x D x H) |
890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in |
|
Weight |
~55 kg |
₹ 78000 / Piece Get Latest Price
| Usage/Application | Industrial Use |
| Packaging Type | carton box |
| brand | anton paar |
| model name | PSA 990 |
| weight | 55 kg |
| dimension | 890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in |
Minimum order quantity: 1 Piece
Anton Paar- PSA 990
· Single laser system
· Measurement range liquid: 0.2 µm to 500 µm
· Measurement range dry: 0.3 µm to 500 µm
Technical specifications
|
|
PSA 990 |
|
Measurement principle |
Laser diffraction |
|
Measuring range (dry) |
0.3 μm to 500 μm |
|
Measuring range (wet) |
0.2 μm to 500 μm |
|
Dry dispersion |
Venturi |
|
Liquid dispersion |
2 peristaltic pumps/ultrasonic transducer/stirrer |
|
Repeatability |
<1 % |
|
Accuracy |
<3 % |
|
Measuring time |
<1 min |
|
Number of lasers |
1 |
|
Laser safety classification |
FDA Title 21 CFR - Part 1040 & EN 60825-1:2014 |
|
Laser class, closed cover |
Class 1 of EN 60825-1:2014 |
|
Laser class, open cover |
Class 3R of EN 60825-1:2014 |
|
Digital data security |
FDA Title 21 CFR - Part 11 |
|
Electromagnetic compatibility |
EN 61326-1:2013 |
|
Low voltage |
EN 61010-1:2010 & EN 61010-2-081:2015 |
|
Dimensions (L x D x H) |
890 mm x 530 mm x 430 mm; 35 in x 21 in x 17 in |
|
Weight |
~55 kg |
₹ 77800 / Piece Get Latest Price
| Brand | anton paar |
| Weight | Ca. 15 kg |
| Dimensions | 262 mm x 506 mm x 486 mm |
| model name | PMA 500 |
| type | Pensky-Martens Flash Point Tester |
| feature | Electric igniter: 10x longer lifetime than competitor products |
Minimum order quantity: 1 Piece
Anton Paar- PMA 500
· The highest sample throughput on the market
· Electric igniter: 10x longer lifetime than competitor products
· Sophisticated feature set, simplifying daily lab work
· Clever design reduces measurement and cleaning time
· Complies to ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T261
Technical specifications
|
|
PMA 500 |
|
Temperature range |
From above ambient temperature to 410 °C |
|
Ignition type |
Electric (encapsulated hot wire) |
|
Cooling after measurement |
Boost mode |
|
Barometric pressure correction |
Flash point is automatically corrected to barometric pressure |
|
Flash detection |
Automatic detection by thermoelement |
|
Sample temperature |
Automatic by Pt100 |
|
Safety |
Automatic fire-extinguishing system in combination with a unique optical fire detection system
Overheat protection, automatic shut-off | Detects a “flash” outside the cup |
|
Calibration |
Calibration of sample and block temperature, stirrer speed, and internal barometer |
|
Memory |
1 GB space for approx. 50,000 tests and 1,000 users |
|
Interfaces |
4 × USB, 1 × LAN |
|
Power supply |
AC 100 V - 120 V, 50/60 Hz |
|
Heating power |
2 × 330 W |
|
Gas supply |
Integrated fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa |
|
Dimensions |
262 mm × 506 mm × 486 mm |
|
Weight |
Ca. 15 kg |
₹ 10000 / Piece Get Latest Price
| Brand | anton paar |
| Weight | 15 kg |
| Dimensions | 262 mm x 497 mm x 477 mm (W x D x H) |
| model name | ABA 500 |
| type | Abel Flash Point Tester |
Technical specifications:
|
|
ABA 500 |
|
|
Test methods |
EN ISO 13736, IP 170 Equilibrium procedures: EN ISO 1523, IP 492, EN 924 | EN ISO 1516, IP 491 >1,000 user-defined test programs |
|
|
Application range (flash point temperature) |
Air-cooled 10 °C to 130 °C Liquid-cooled -30 °C to +130 °C |
|
|
Sample temperature range |
Air-cooled -7 °C to 130 °C Liquid-cooled -35 °C to +130 °C |
|
|
Ignition type |
Electric (encapsulated hot wire) |
|
|
Stirring speed |
According to standard or user-defined |
|
|
Heating rate |
According to standard or user-defined |
|
|
Cooling |
Fan- and liquid-supported Peltier cooling technology |
|
|
Barometric pressure correction |
Flash point is automatically corrected to barometric pressure |
|
|
Flash detection |
Automatic detection by thermocouple |
|
|
Sample temperature |
Automatic by Pt100 |
|
|
Safety |
|
|
|
Calibration |
Calibration of sample and block temperature, stirrer speed, and internal barometer |
|
|
Handling |
TFT touchscreen | Small footprint |
|
|
Memory |
1 GB space for approx. 50,000 tests and 1,000 users |
|
|
Statistics |
Mean, min, max, repeatability, standard deviation, max. deviation |
|
|
Interfaces |
4 × USB, 1 × LAN |
|
|
Input options |
Optional USB keyboard/mouse/barcode reader |
|
|
Display |
7" TFT, PCAP touchscreen |
|
|
Power supply |
100 V to 240 V, 50/60 Hz, 300 W |
|